GovBidAlerts
← My Opportunities
open🌐 RFPMart: USA (all categories)http://www.rfpmart.com/1131663-us-fed-w065--agiliti-laser-fusionand-ultra-sound.html

US-FED-00000382900 - W065--AGILITI LASER, FUSION,AND ULTRA SOUND - Deadline June 19,2026

Description

The Department of Veterans Affairs, Network Contracting Office (NCO) 6, intends to enter into a sole source contract with AGILITI HEALTH, INC.     This requirement is for rentals of mobile laser machines assisted by licensed and credentialed technicians. Description of service/supplies being requested: Argon Beam Coagulator, Argon Beam Coagulator Stand By, CO2 laser, CO2 laser Stand By, Holmium Laser Low Wattage, Holmium Laser Low Wattage Stand By, Aura XP Laser, Aura XP Laser Stand By, Aura Accustat Fiber, KTP Laser, KTP Laser Stand by, OmniGuide Laser, OmniGuide Laser Stand By, UltraPulse CO2 Laser, UltraPulse CO2 Laser Stand By, XPS Laser, XPS Laser Stand By, Ultrasound.  SALIENT CHARACTERISTICS 1. General Requirements (All Equipment) All systems provided shall: 1. Be commercial, mobile, and suitable for hospital Operating Room environments. 2. Arrive fully functional, calibrated, and ready for immediate use. 3. Include all necessary accessories, cables, disposables, and interface components required for operation. 4. Be compatible with the facility s standard electrical supply and OR workflows. 5. Include a trained technician capable of setup, operation support, and troubleshooting. 6. Include access to a backup unit when required to avoid case cancellation or delays. 2. Surgical Laser Systems Minimum Functional Requirements The contractor shall provide laser systems meeting the following minimum capabilities across the full range of requested surgical modalities (CO , Holmium, KTP, Argon Beam, etc.): 2.1 CO Laser Systems Capable of performing ablative, coagulative, and cutting functions. Provide adjustable power output suitable for ENT, dermatologic, gynecologic, and urologic procedures. Support both focused beam and fiber delivered energy delivery (where applicable). Include a range of handpieces, adapters, or fiber delivery options sufficient for common procedures. Deliver a spot size suitable for precision surgical applications (e.g., fine cutting ENT work). 2.2 Holmium (Standard & High Power) Capable of lithotripsy, soft tissue ablation, and urologic surgical interventions. Deliver fiber based laser energy via holmium compatible fibers. Variable power settings suitable for both low and high power applications. 2.3 KTP & Greenlight Type Lasers Capable of photoselective vaporization and coagulation for urologic and ENT procedures. Support delivery of energy through standard disposable or reusable fibers. 2.4 Argon Beam Coagulator Provide non contact argon plasma coagulation for open surgical procedures. Deliver precise, controllable coagulation for tissue desiccation. 2.5 Vbeam / Pulsed Dye Laser (if requested) Provide pulsed energy delivery for dermatologic vascular applications. Adjustable pulse width and energy settings appropriate for clinical use. 3. Cryoablation System Minimum Functional Requirements Cryoablation systems shall: Provide percutaneous or intraoperative cryotherapy using argon based or equivalent technology. Support manufacturer approved cryoprobes appropriate for urologic cryoablation. Include temperature monitoring and control features. Provide freeze thaw cycles capable of ablative tissue destruction. Be mobile and operable in a standard OR suite. 4. Fusion Biopsy System Minimum Functional Requirements Fusion Biopsy equipment shall: Support real time fusion of pre operative MRI images with live ultrasound imaging. Be compatible with the contractor provided ultrasound system (e.g., BK5000 type capability). Include biopsy guides, grids, or stabilizers appropriate for targeted prostate biopsy. Support acquisition, alignment, and guidance for targeted tissue sampling. Provide workstation/software capable of image fusion, contouring, and biopsy path visualization. 5. Ultrasound System (BK Type) Minimum Functional Requirements The ultrasound system provided shall: Provide real time imaging suitable for urologic and surgical applications. Include transducers/probes appropriate for fusion biopsy and intraoperative imaging. Include system specific disposable items such as biopsy guides, if required. Provide image quality adequate for lesion targeting, guidance, and intraoperative visualization. 6. Technician Requirements (As Salient Characteristics) Technicians supplied must: Have a minimum of 2 years experience operating the equipment assigned. Be manufacturer trained and certified on each modality supported. Be trained in laser safety and applicable clinical safety policies. Arrive at least 30 minutes before the procedure or earlier if required. Be available within 30 minutes for emergency or after hours support. Be capable of performing setup, safe operation, and troubleshooting. 7. Safety & Compliance Requirements The equipment and technicians must comply with: All applicable FDA classifications for medical devices. OR laser safety standards and facility policies. Infection control and cleaning requirements. HIPAA and privacy protections (for any recorded patient data

Details

Posted
Jun 17, 2026
Response deadline
Jun 19, 2026, 11:59 PM UTC
Status
open
Jurisdiction
RFPMart: USA (all categories)
Item
US-FED-00000382900 - W065--AGILITI LASER, FUSION,AND ULTRA SOUND - Deadline June 19,2026 The Department of Veterans Affairs, Network Contracting Office (NCO) 6, inte
Finding similar opportunities…

This listing is a summary from RFPMart: USA (all categories)'s open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.