Award NoticeActiveW912PP26QA0020
Conchas Equipment Storage Structure
DEPT OF DEFENSE / DEPT OF THE ARMY / W075 ENDIST ALBUQUERQUEKey dates?
- Posted?
- Jul 10, 2026
- Response deadline?
- —
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Award Notice
- Base type?
- Award Notice
- Set-aside?
- 8(a) Sole Source
- Set-aside code?
- 8AN
- PSC?
- Z2JZ
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE ARMY
- Office?
- W075 ENDIST ALBUQUERQUE
- Office code?
- 021.2100.USACE.SPD.SPA.W912PP
- Organization type?
- OFFICE
- Office address?
- ALBUQUERQUE, NM, 87109-3435, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Conchas Dam
- State?
- New Mexico
- Zip?
- 88416
- Country?
- UNITED STATES
Contacts?
- Glenda D. Kohlieberprimary
Description?
This action was awarded as an 8(a) Sole Source Set-Aside under the authority of section 8(a) of the Small Business Act. Contractor shall furnish all labor, materials, equipment, and supervision required for the purchase and construction of a 30 ft. x 60 ft. metal equipment structure located at Conchas Dam, New Mexico. The Pre-engineered Metal Building package shall have Professional Engineer stamped drawings certifying the building fit, form, and function. Subgrade and Compaction: The Contractor shall scarify, compact, and grade the subgrade in preparation for the concrete footer. Soil must be compacted to a minimum of 95% of its maximum dry density as determined by standard testing methods. As a condition precedent to the placement of any concrete, the Contractor shall conduct soil compaction testing through an independent, qualified testing laboratory. A certified report detailing all test locations, methods, and results shall be formally submitted to the Government Representative.Perimeter Footings with Piers: The Contractor shall be responsible for the complete design and construction of a reinforced concrete footer system adequate to support the steel equipment structure.Foundation and Anchoring: Structural columns shall be anchored to pier foundations on the concrete footer. The foundation design must meet the building manufacturer’s recommendations and be stamped by a Professional Engineer
Award?
- Number?
- W912PP26PA013
- Amount?
- $243,181.00
- Date?
- —
- UEI?
- PMS1CQNE7YH4
- Awardee address?
- Des Moines, New Mexico, 88418, UNITED STATES
Similar open contracts
Metadata?
- Notice ID?
- d3f02d3865054b13ae174890b23b82c9
- Full path?
- DEPT OF DEFENSE.DEPT OF THE ARMY.W075 ENDIST ALBUQUERQUE
- Office code?
- 021.2100.USACE.SPD.SPA.W912PP
- Ingested?
- Jul 11, 2026
- Updated?
- Jul 11, 2026