SolicitationActive36C24226R0060
Y1DA--630A4-26-401 MRI AHU Modification
VETERANS AFFAIRS, DEPARTMENT OF / VETERANS AFFAIRS, DEPARTMENT OF / 242-NETWORK CONTRACT OFFICE 02 (36C242)Key dates?
- Posted?
- Aug 26, 2026
- Response deadline?
- Aug 28, 2026, 4:00 PM UTC
- Archive date?
- Sep 27, 2026
- Archive type?
- autocustom
Classification?
- Notice type?
- Solicitation
- Base type?
- Solicitation
- Set-aside?
- —
- Set-aside code?
- —
- PSC?
- Y1DA
NAICS?
Issuing office?
- Department?
- VETERANS AFFAIRS, DEPARTMENT OF
- Sub-tier?
- VETERANS AFFAIRS, DEPARTMENT OF
- Office?
- 242-NETWORK CONTRACT OFFICE 02 (36C242)
- Office code?
- 036.3600.36C242
- Organization type?
- OFFICE
- Office address?
- ALBANY, NY, 12208, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- —
- State?
- —
- Zip?
- —
- Country?
- —
Contacts?
- Kimberly A Gomez (Contractor)primaryContract Specialist
Description?
36C24226R0060 Amendment 5 630A4-26-401 MRI AHU Modification 8. Question -Hallway Fan Coil Units-The contract documents indicate (6) 18,000 BTU/h chilled water surface-mounted fan coil units in the hallway. We have concerns with this configuration: the surface-mounted units would protrude into the corridor, presenting both an aesthetic issue and a potential head-strike hazard for pedestrians. We propose substituting ceiling-mounted fan coil units in lieu of the surface-mounted units. Please advise which of the following options is acceptable: VA Response: Option A would be acceptable if there is no additional cost to the VA. Six ceiling mounted units would provide both the desired level of equipment redundancy and distributed air flow equivalent to the contract design wall mounted units. An 18,000 btu wall mounted evaporator fan unit requires a minimum of 6 inches of clearance below the ceiling for proper air flow. As the evaporator fan coil unit is approximately 12-14 inches high, in an 8 foot high corridor (96 inches clear), there would be a minimum of 76 inches clearance under the evaporator fan unit, or 6 foot 3 inches. If the corridor is higher than 8 feet then the clearance would increase. Option A: Provide (6) ceiling-mounted fan coil units at 18,000 BTU/h each; note that due to ceiling constraints, the units cannot be equally spaced along the corridor. Option B: Provide (3) ceiling-mounted fan coil units of higher capacity, sized to provide equivalent total cooling capacity, spaced evenly along the corridor.
Attachments (22)?
- Download📎 S02+INSTRUCTIONS+TO+BIDDERS+REGARDING+TAX+EXEMPTION+IN+NY+2.1.docxapplication/octet-stream · 18 KB
- Download📎 S02+FAR+DEVIATION+FEB+2025+NOTICE+2.1.docxapplication/octet-stream · 15 KB
- Download📎 S02+SAFETY+AND+ENVIRONMENTAL+RECORD+2.1.docxapplication/octet-stream · 16 KB
- Download📎 P02+Drawings.pdfapplication/pdf · 3.0 MB
- Download📎 36C24226R0060+0001.docxapplication/octet-stream · 19 KB
- Download📎 S02+AUTODESK+Contractors+Access+Instructions+1.1.pdfapplication/pdf · 1.1 MB
- Download📎 S02+LIMITATION+ON+SUBCONTRACTING+2.1.docxapplication/octet-stream · 16 KB
- Download📎 SOW+12152025.docxapplication/octet-stream · 39 KB
- Download📎 36C24226R0060_1.docxapplication/octet-stream · 124 KB
- Download📎 36C24226R0060+0002.docxapplication/octet-stream · 19 KB
- Download📎 S02+Privacy+Training+for+Personnel+without+Access+to+VA+Computer+1.1.pdfapplication/pdf · 62 KB
- Download📎 S02+Participation+Goals+for+Minorities+and+Females+2.1.pdfapplication/pdf · 414 KB
- Download📎 SCA+2015_4187_34+12032025.docxapplication/octet-stream · 7.8 MB
- Download📎 36C24226R0060+0005.docxapplication/octet-stream · 18 KB
- Download📎 Phase+II+Proposals.docxapplication/octet-stream · 22 KB
- Download📎 S02+Specifications.pdfapplication/pdf · 607 KB
- Download📎 S02+Supplement+A+though+C.pdfapplication/pdf · 616 KB
- Download📎 S02+52.225-2+BUY+AMERICAN+CERTIFICATE+2.1.docxapplication/octet-stream · 16 KB
- Download📎 36C24226R0060+0003.docxapplication/octet-stream · 19 KB
- Download📎 WD+NY20260003+01302026.docxapplication/octet-stream · 5.5 MB
- Download📎 Instructions+to+Offers.docxapplication/octet-stream · 352 KB
- Download📎 36C24226R0060+0004.docxapplication/octet-stream · 54 KB
Other notices in this solicitation?
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJul 31, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJul 23, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJul 23, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJun 30, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJun 30, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationJun 18, 2026
- Award NoticeY1DZ--NRM-CONST 630-26-200 NYH Repair Underground Storage TanksMay 20, 2026
- SolicitationY1DA--630A4-26-401 MRI AHU ModificationApr 27, 2026
- PresolicitationY1DA--630A4-26-401 MRI AHU ModificationApr 7, 2026
Similar open contracts
Metadata?
- Notice ID?
- b1097a4265794540b53e23fffb553541
- Full path?
- VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.242-NETWORK CONTRACT OFFICE 02 (36C242)
- Office code?
- 036.3600.36C242
- Ingested?
- Aug 27, 2026
- Updated?
- Sep 13, 2026