GovBidAlerts
← All opportunities
This notice has been superseded. See the latest notice: Repair Naval Reserve Training Facility B3370 (Sources Sought)

Repair Natural Resources Facility B3370

Key dates

Posted
Mar 17, 2026
Response deadline
Apr 1, 2029, 4:00 PM UTC
Archive date
Archive type
auto15

Classification

Notice type
Sources Sought
Base type
Sources Sought
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Set-aside code
SBA
PSC
Z2AA

NAICS

Issuing office

Department
DEPT OF DEFENSE
Sub-tier
DEPT OF THE AIR FORCE
Office
FA4418 628 CONS PK
Office code
Organization type
OFFICE
Office address
JOINT BASE CHARLESTON, SC, 29404-5021, USA

Place of performance

Street
Street 2
City
Charleston AFB
State
SC
Zip
29404
Country
USA

Contacts

Description

The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Natural Resources Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 – Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00

Other notices in this solicitation

Similar open contracts

Metadata

Notice ID
a6d873bcd46e4e77beecf35c52675c4d
Full path
DEPT OF DEFENSE.DEPT OF THE AIR FORCE.FA4418 628 CONS PK
Office code
Ingested
May 2, 2026
Updated
Jul 11, 2026