Combined Synopsis/SolicitationActiveFA440726Q1000
FY26 750kVA 3-Phase Transformer
DEPT OF DEFENSE / DEPT OF THE AIR FORCE / FA4407 375 CONS LGCKey dates?
- Posted?
- Jun 4, 2026
- Response deadline?
- Jun 12, 2026, 5:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Combined Synopsis/Solicitation
- Base type?
- Combined Synopsis/Solicitation
- Set-aside?
- Total Small Business Set-Aside (FAR 19.5)
- Set-aside code?
- SBA
- PSC?
- 6120
NAICS?
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE AIR FORCE
- Office?
- FA4407 375 CONS LGC
- Office code?
- 057.5700.AMC.FA4407
- Organization type?
- OFFICE
- Office address?
- SCOTT AFB, IL, 62225-5015, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Scott Air Force Base
- State?
- Illinois
- Zip?
- 62225
- Country?
- UNITED STATES
Contacts?
- Margret Westprimary
- Christopher Greenesecondary
Description?
Request the purchase of the product listed below. This acquisition is being procured utilizing NAICS Code 335311 Power, Distribution, and Specialty Transformer Manufacturing: Ballasts Lamp holders, and Starters Size Standard 600 Employees and PSC Code 6120, Transformers: Distribution and Power Station. This requirement will be a Small-Business Set-Aside. Using RFO Part 12 procedures, 375th CONS intends to evaluate submitted quotes using Lowest Price Technically Acceptable (LPTA) criteria, and a single award will be made. To be considered for award, offerors must have an active registration in SAM. Please provide an offer for the product listed below by: 10:00 A.M. CST 5 June 2026. (All RFQ info and Transformer Specs are attached) Copper Windings Required - Updated 4Jun26 kVA - 750 kVA 3 Phase Pad-Mount Transformer Insulating fluid - Envirotemp FR3 Efficiency Standard - DOE 2016 High Voltage - 12470GY/7200 Volts High Voltage kV Class - 15 kV Class High Voltage kV BIL - 95 kV BIL Primary Termination Style - Dead Front Primary Feed Type - Loop Feed Taps - 2 - 2.5% taps above and 2 - 2.5% taps below nominal Tap Changer - 5-position tap changer Tap Changer Switch Location - Frontplate HV Compartment High Voltage Bushings - 200 amp Cooper bushing wells with removable studs (Quantity: 6) Primary Ground Bushing Selection - Combined H0X0 Bushing High Voltage Inserts - 15 kV, 95 kV BIL load-break inserts (Quantity: 6) Loadbreak Switch(es) - 15-38 kV, 300A 2-Position (Quantity: 3) Loadbreak Switch Location - Frontplate HV Compartment High Voltage Arresters - Varistar elbow arresters, 15 kV class, distribution class 15 kV (Quantity: 3) Overcurrent Protection Bayonet Fuses in series with Partial-Range Current-Limiting Fuses (Quantity: 3) Expulsion fuses Bayonet fuses - (Quantity: 3) Bayonet Holder - Copper Bayonet Fuse Holder (Quantity: 3) Low Voltage - 480Y/277 Volts Low Voltage kV Class - 1.2 kV Class Low Voltage kV BIL - 30 kV BIL Secondary Termination Style - Live Front Secondary Feed Type - Radial Feed Low Voltage Bushing Location - LV Frontplate (seg 1) Low Voltage Bushings - Integral aluminum 12-hole spade bushing(s) (Quantity: 4) Bushing Supports - Standard LV Bushing Support Assembly Cabinet hardware - Penta-head cabinet door bolts Cabinet Types - IEEE/ANSI Infrared Viewing Windows - No Window Required Bushing Layout - K 4.5 Loop feed per IEEE C57.12.34-2022 Figure 11 minimum dimensions (without bails) Special Paint - Federal Spec Number Sherwin Williams 6006, Black Bean Brown Cabinet Sill Construction - 304L Stainless steel cabinet sill Cabinet Sides Construction - 304L Stainless steel cabinet sides Tank Base Construction - 304L Stainless steel tank base FM / UL Certifications - UL Listed Liquid Level Gauge - Magnetic liquid level gauge Pressure Vacuum Gauges - Pressure/vacuum gauge Thermometer - Thermometer, dial-type Other Fittings - Schrader valve Drain Valve - Drain valve with sampler in LV Compartment (1") Fill Valve - Fill plug in LV Compartment Pressure Relief Device - Pressure relief device, 50 SCFM Ground Pads - Two-hole ground pads (Quantity: 3) Nitrogen Blanket - Yes Cover Bolted cover Gauges Location Inside Main Cabinet on Front Plate
Attachments (9)?
- Download📎 SAM+RFQ.docxapplication/octet-stream · 43 KB
- Download📎 Amendment+04+-+FY26+750kVA+3-Phase+Transformer+-+FA440726Q1000_cao4Jun26.pdfapplication/pdf · 223 KB
- Download📎 CLSExport_FA440726Q1000.pdfapplication/pdf · 22 KB
- Download📎 Amendment+01+-+FY26+750kVA+3-Phase+Transformer+-+FA440726Q1000.pdfapplication/pdf · 192 KB
- Download📎 QandA_Updated+04June26_MHW.pdfapplication/pdf · 67 KB
- Download📎 Amendment+03+-+FY26+750kVA+3-Phase+Transformer+-+FA440726Q1000_cao3Jun26.pdfapplication/pdf · 220 KB
- Download📎 QandA_Updated+03June26_MHW.pdfapplication/pdf · 63 KB
- Download📎 Updated+4Jun26_Transformer+Specs.docxapplication/octet-stream · 29 KB
- Download📎 Amendment+02+-+FY26+750kVA+3-Phase+Transformer+-+FA440726Q1000.pdfapplication/pdf · 217 KB
Other notices in this solicitation?
- Combined Synopsis/SolicitationFY26 750kVA 3-Phase TransformerJun 3, 2026LATEST
- Combined Synopsis/SolicitationFY26 750kVA 3-Phase TransformerMay 29, 2026LATEST
- Combined Synopsis/SolicitationFY26 750kVA 3-Phase TransformerMay 27, 2026LATEST
- Combined Synopsis/SolicitationFY26 750kVA 3-Phase TransformerMay 26, 2026LATEST
Similar open contracts
Metadata?
- Notice ID?
- 9eeae59c2816404eb92f475aed1e6399
- Full path?
- DEPT OF DEFENSE.DEPT OF THE AIR FORCE.FA4407 375 CONS LGC
- Office code?
- 057.5700.AMC.FA4407
- Ingested?
- Jun 5, 2026
- Updated?