GovBidAlerts
← All opportunities

J012--575 Fire System Inspection & Repairs - one year only

Key dates

Posted
Jun 25, 2026
Response deadline
Jun 29, 2026, 6:00 PM UTC
Archive date
Archive type
autocustom

Classification

Notice type
Combined Synopsis/Solicitation
Base type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Set-aside code
SBA
PSC
J012

NAICS

Issuing office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
NETWORK CONTRACT OFFICE 19 (36C259)
Office code
036.3600.36C259
Organization type
OFFICE
Office address
Greenwood Village, CO, 80111, USA

Place of performance

Street
Department of Veterans Affairs VA Western Colorado Healthcare System 2121 North ave
Street 2
VA Western Colorado Healthcare System 2121 North ave
City
Grand Junction
State
CO
Zip
81501
Country

Contacts

Description

Q&A Solicitation # 36C25926Q0519 The purpose of this amendment is to: Provide answers to questions received under solicitation 36C25926Q0519. To provide the Joint Commission review tool and clarification document to add awareness for prospective contractors regarding the standards for completing repairs and inspections (see attached). All offers are to be emailed to heather.chase2@va.gov and received no later than 12:00pm (noon) MT on June 29, 2026. Questions and Answers below are referencing RFQ 36C25926Q0519: Q. Will the Government please provide the number of Wet Systems per building? B1: 1 B5: 1 B6: 1 B7: 1 B8: 1 B12: 1 B13: 1 B20: 1 B22: 1 B33: 1 B34: 1 B36: 1 B45: 1 . Q. What is the total number of Dry Systems per building? A. Not in scope of the required repairs. Q. What is the total number of Pre-Action Systems? A. None, station is wet-piped. Q. What is the total number of Deluge Systems? A. Not in scope of required repairs. Q. What is the total number of Backflow Preventers?. A. Not in scope of required repairs. Q. What is the total number of Fire Pumps? A. Not in scope of required repairs. Q. What is the total number of Control Valves? A. Please see CLIN 3 (page 5 & 6) of Attachment 1 - SOW. Q. What is the total number of Flow Switches? A. Please see CLIN 3 (page 5 & 6) of Attachment 1 - SOW. Q. What is the total number of Pressure Regulating Valves PRV? A. Not in scope of required repairs.

Attachments (28)

Other notices in this solicitation

Similar open contracts

Metadata

Notice ID
962478af97e64fdfa4c3a0dee1378588
Full path
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.NETWORK CONTRACT OFFICE 19 (36C259)
Office code
036.3600.36C259
Ingested
Jun 26, 2026
Updated
Jul 11, 2026