GovBidAlerts
← All opportunities

AIRFIELD LEAKING TRANSFORMER

Key dates

Posted
Jul 22, 2026
Response deadline
Aug 3, 2026, 4:00 PM UTC
Archive date
Archive type
auto15

Classification

Notice type
Combined Synopsis/Solicitation
Base type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Set-aside code
SBA
PSC
J061

NAICS

Issuing office

Department
HOMELAND SECURITY, DEPARTMENT OF
Sub-tier
US COAST GUARD
Office
BASE CAPE COD(00052)
Office code
070.7008.70Z052
Organization type
OFFICE
Office address
BUZZARDS BAY, MA, 02542, USA

Place of performance

Street
Street 2
City
Buzzards Bay
State
Massachusetts
Zip
02542
Country
UNITED STATES

Contacts

Description

SCOPE: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to remove and dispose of existing airfield lighting transformers and replace with new (Fig. 1-11) at the U.S. Coast Guard, Base Cape Cod, on Joint Base Cape Cod, Buzzards Bay, MA, 02542. Existing transformers: Contractors shall verify transformer specifications. Transformer 413 (Fig. 1-3), adjacent to building 614 and runway 23. MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 ½, 65° RISE, serial number 74ZD743004, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % IMP. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 – SWITCH POSITION 2.4, VOLTAGE 7200 – SWITCH POSITION 7.2, VOLTAGE 7970 – SWITCH POSITION 7.9 Transformer 523 (Fig. 4-6), adjacent to building 614 and runway 14, MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 ½, 65° rise, serial number 73ZE858030, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % imp. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 – SWITCH POSITION 2.4, VOLTAGE 7200 – SWITCH POSITION 7.2, VOLTAGE 7970 – SWITCH POSITION 7.9 Transformer 232177 (Fig. 7-9), adjacent to building 3181 parking. MANUFACTURER - ABB, Power System Division, Jefferson City, MD, 21755, Three phase distribution, 60 hertz, KVA 1500/1680, 55/65° RISE, style number F3HF147L66, serial number 11JC572250001, MFG Date Jun-11, voltage rating 22860GRDy13200, HV BIL KV 125, HV MTL AL, % Impedance 5.75, Low voltage 4160Y/2400, LV BIL KC 60, LV MTL AL, Mineral Oil 513 Gallons. NOTE: The Contractor shall investigate and determine the existence of oil leaks and provide analysis/feasibility for replacement or repair. Option Bid: Transformer 575 (Fig. 10-12), adjacent to building 195 and runway 5, Manufacturer Southeastern Transformer Co, Dunn, NC, single phase, 60 hertz, KVA 15, % imp. 3.6, serial number 1019102, volts 12470GRDY/7200-240/120. SEE SOW FOR FULL REQUIREMENTS

Attachments (3)

  • 📎 SOW+Replace+Airfield+Transformers+%283%29+with+%281%29+option.doc
    application/octet-stream · 8.9 MB
    Download
  • 📎 DBA+WAGES+BARNSTABLE+COUNTY.txt
    application/octet-stream · 55 KB
    Download
  • 📎 Transformer_Standard+Form+1449+-+Solicitation_Contract_Order+for+Commercial+Products+and+Commercial+Services.pdf
    application/pdf · 802 KB
    Download

Similar open contracts

Metadata

Notice ID
7bfe13e4701c4726bbf86a26da59aed4
Full path
HOMELAND SECURITY, DEPARTMENT OF.US COAST GUARD.BASE CAPE COD(00052)
Office code
070.7008.70Z052
Ingested
Jul 23, 2026
Updated
Jul 24, 2026