GovBidAlerts
← All opportunities

6530--Retrofit Washer Disinfector

Key dates

Posted
Jul 9, 2026
Response deadline
Jul 17, 2026, 9:00 PM UTC
Archive date
Archive type
autocustom

Classification

Notice type
Combined Synopsis/Solicitation
Base type
Combined Synopsis/Solicitation
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Set-aside code
SBA
PSC
6530

NAICS

Issuing office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
248-NETWORK CONTRACT OFFICE 8 (36C248)
Office code
036.3600.36C248
Organization type
OFFICE
Office address
TAMPA, FL, 33637, USA

Place of performance

Street
James A. Haley Veterans Hospital 13000 Bruce B. Downs Blvd Tampa, FL
Street 2
Tampa, FL
City
State
Zip
33612
Country
UNITED STATES

Contacts

Description

Retrofit Washer Disinfector with AcuDose System GENERAL: James A. Haley Veterans Hospital (JAHVH), located at 13000 Bruce B. Downs Blvd, Tampa, FL 33612, has a requirement for the Steris AcuDose Retrofit Kit for 7053HP Washer Disinfectors to support compliant chemical dosing operations in the Sterile Processing Service (SPS). BACKGROUND: The Sterile Processing Service (SPS) currently provides critical instrument reprocessing functions that depend on accurate chemical dosing and reliable washer disinfector performance. The existing Steris Amsco 7053HP washers were installed before AcuDose technology was available, and SPS now relies on eighteen aging chemical delivery lines that no longer meet operational or reliability requirements. To ensure continued compliance with national standards, maintain compatibility with existing Steris systems, and improve dosing accuracy, workflow consistency, and overall performance, SPS requires an OEM approved equipment upgrade that retrofits the current 7053HP washers with the AcuDose system and replaces the outdated delivery lines. SCOPE: The contractor shall furnish all labor, materials, and OEM certified Steris technicians to provide and install the Steris brand name AcuDose Retrofit Kit for the 7053HP Washer Disinfectors. Use of the Steris brand name AcuDose Retrofit Kit is required to ensure full system compatibility, maintain standardization of Steris equipment across the facility, and preserve warranty and safety requirements. The contractor shall disconnect, extract, and remove all eighteen (18) existing chemistry delivery lines routed through PVC conduits from the dosing room to the washers. Following removal, the contractor shall install and retrofit the AcuDose system on the three (3) 7053HP washer disinfectors located in the SPS decontamination area. All retrofit work shall be performed one washer at a time to maintain continuous SPS operations. This project requires no FMS support, as no electrical or plumbing modifications are needed. Upon installation of each AcuDose retrofit, the contractor shall verify proper system operation and functionality. The contractor shall also provide on site in service training to SPS staff to ensure correct operation of the upgraded equipment. All work must be performed in accordance with applicable VA standards and exclusively by technicians certified to work on Steris equipment.