This notice has been superseded. See the latest notice: Chiller Replacement Roybal Campus (Solicitation)
PresolicitationActive75D301-26-R-73398
Chiller Replacement Roybal Campus
HEALTH AND HUMAN SERVICES, DEPARTMENT OF / CENTERS FOR DISEASE CONTROL AND PREVENTION / CDC OFFICE OF ACQUISITION SERVICESKey dates?
- Posted?
- Apr 23, 2026
- Response deadline?
- May 8, 2026, 9:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Presolicitation
- Base type?
- Presolicitation
- Set-aside?
- Total Small Business Set-Aside (FAR 19.5)
- Set-aside code?
- SBA
- PSC?
- Z2AA
NAICS?
Issuing office?
- Department?
- HEALTH AND HUMAN SERVICES, DEPARTMENT OF
- Sub-tier?
- CENTERS FOR DISEASE CONTROL AND PREVENTION
- Office?
- CDC OFFICE OF ACQUISITION SERVICES
- Office code?
- —
- Organization type?
- OFFICE
- Office address?
- ATLANTA, GA, 30333, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- —
- State?
- GA
- Zip?
- 30329
- Country?
- USA
Contacts?
- Simi Kheraprimary
Description?
This acquisition supports modernization of Building 10 (central plant) at the CDC Roybal Campus in Atlanta, Georgia. The objective is to provide complete design-build services to replace aging chilled-water plant equipment, improve electrical and controls infrastructure, maintain continuity of campus operations during phased execution, and deliver a fully commissioned and documented facility. a. Provide all design, engineering, management, supervision, labor, materials, equipment, testing, commissioning, training, and closeout services required to modernize the B10 chilled-water plant. b. Replace four existing 1,450-ton chillers with new 1,800-ton chillers and provide associated starters, controls, piping, isolation valves, refrigerant monitoring, and appurtenances. c. Replace nine existing cooling tower cells with eight new cells; provide structural modifications, walkways, maintenance access, valves, piping, and roofing work required for the new configuration. d. Replace primary chilled-water pumps, condenser-water pumps, associated starters / VFDs, and modify chilled-water and condenser-water piping as required for the new plant arrangement. e. Perform associated medium-voltage and low-voltage electrical upgrades, BAS / controls integration, structural work, fire protection modifications, and ancillary systems work identified in Attachment A. f. Provide phased execution that preserves campus operations; no more than two chillers may be removed from service at one time.
Other notices in this solicitation?
- SolicitationChiller Replacement Roybal CampusJun 22, 2026LATEST
- SolicitationChiller Replacement Roybal CampusJun 16, 2026
- SolicitationChiller Replacement Roybal CampusJun 8, 2026
- SolicitationChiller Replacement Roybal CampusJun 3, 2026
- SolicitationChiller Replacement Roybal CampusMay 27, 2026
- SolicitationChiller Replacement Roybal CampusMay 11, 2026
Similar open contracts
Metadata?
- Notice ID?
- 65c339ef598846d8a78c2a9fea098b7b
- Full path?
- HEALTH AND HUMAN SERVICES, DEPARTMENT OF.CENTERS FOR DISEASE CONTROL AND PREVENTION.CDC OFFICE OF ACQUISITION SERVICES
- Office code?
- —
- Ingested?
- May 2, 2026
- Updated?
- May 3, 2026