SolicitationActive36C25226Q0521_2
ULTRASOUND
VETERANS AFFAIRS, DEPARTMENT OF / VETERANS AFFAIRS, DEPARTMENT OF / 252-NETWORK CONTRACT OFFICE 12 (36C252)Key dates?
- Posted?
- Jul 7, 2026
- Response deadline?
- Jul 21, 2026, 3:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Solicitation
- Base type?
- Solicitation
- Set-aside?
- Service-Disabled Veteran-Owned Small Business Set Aside
- Set-aside code?
- SDVOSBC
- PSC?
- 6515
NAICS?
Issuing office?
- Department?
- VETERANS AFFAIRS, DEPARTMENT OF
- Sub-tier?
- VETERANS AFFAIRS, DEPARTMENT OF
- Office?
- 252-NETWORK CONTRACT OFFICE 12 (36C252)
- Office code?
- 036.3600.36C252
- Organization type?
- OFFICE
- Office address?
- MILWAUKEE, WI, 53214, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Milwaukee
- State?
- Wisconsin
- Zip?
- 53295
- Country?
- UNITED STATES
Contacts?
- Vernise L. Newtonprimary
Description?
ELLEX ABSOLU S ULTRASOUND CONSOLE WITH A-STD PROBE (P/N PCBX0037S1S) QTY:1 ELLEX BIOMETRY A-SCAN PROBE FOR ABSOLU Ground plate w/o filter QTY:2 ELLEX 15 MHz B PROBE FOR ABSOLU/ABSOLU S QTY:2 50 MHz LINEAR HIGH-RESOLUTION PROBE FOR ABSOLU/ABSOLU S SYSTEMS ONLY QTY:1 STANDARDIZED A PROBE (PROBE ONLY) FOR ABSOLU S MODULES ONLY QTY:5 ELLEX BOX OF CLEARSCANS QTY:1 ELLEX DICOM SOFTWARE FOR ABSOLU ULTRASOUND QTY:1 ELLEX WIRELESS 9 FUNCTION FOOTSWITCH FOR ABSOLU/ABSOLU S QTY:1 ELLEX ULTRASOUND CART FOR ABSOLU & COMPACT TOUCH 2 QTY:1 ELLEX ULTRASOUND CLINICAL APPLICATIONS TRAINING QTY:1 Salient Characteristics Brand Name or Equal: A-scan Biometry: to verify measurements of the length of the eye (axial length) -Immersion A-scan -Direct contact A-scan -QTY Two (2) Biometry A-scan transducers -Auto Axial length average and standard deviation calculations -IOL Formulas -Lens Database -measurement tools B-scan 15 MHz B-scan probe -Qty Two (2) Biometry B-scan transducers UBM -QTY One (1) UBM Transducer -QTY Ten (10) single-use sterile UBM-probe cover devices -QTY Six (6) 8-MHz A-scan diagnostic transducers allows for: diagnosis of tumor lesions, diagnosis of retinal vitreous membrane detachment and diagnosis of Graves disease -probe positioning feedback/visualization -Static and dynamic image capture and storage -Image Annotation -pachymetry probe self-check/auto calibration -DICOM networking, compatibility to send to Ziess Forum -Footswitch -height-adjustable cart with keyboard tray -1-day on-site Clinical Applications training to identify sight threatening retinal lesions, such as ocular tumors measurements critical in determining what power lens implant to place in the eye after cataract surgery -Sulcus-to-Sulcus measurements -corneal thickness measurements -IOP correction formulas VA Networked Medical Device risk assessment documents: VA Directive 6550 Ports, Protocols, and Security spreadsheet Inventory List MDS2 Network Topology Diagram Software Bill of Materials A Letter of support is required if there is any vendor proprietary firmware, customized OS, or COTS Devices (i.e. NAS, Firewall, switch, HW load balancer, etc.)
Attachments (1)?
- Download📎 36C25226Q0521_2.docxapplication/octet-stream · 207 KB
Similar open contracts
Metadata?
- Notice ID?
- 406eb5b940af4a8fac36cebf03901f4f
- Full path?
- VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.252-NETWORK CONTRACT OFFICE 12 (36C252)
- Office code?
- 036.3600.36C252
- Ingested?
- Jul 8, 2026
- Updated?
- Jul 11, 2026