Sources SoughtActivePANNGB26P0000038507
Fire Suppression Backflow preventer
DEPT OF DEFENSE / DEPT OF THE ARMY / W7M9 USPFO ACTIVITY KSANG 184Key dates?
- Posted?
- Jul 9, 2026
- Response deadline?
- Jul 20, 2026, 2:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Sources Sought
- Base type?
- Sources Sought
- Set-aside?
- Total Small Business Set-Aside (FAR 19.5)
- Set-aside code?
- SBA
- PSC?
- J012
NAICS?
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE ARMY
- Office?
- W7M9 USPFO ACTIVITY KSANG 184
- Office code?
- 021.2100.NGB.JFHQ USPFO KS.USPFO KS PROC.W50S7X
- Organization type?
- OFFICE
- Office address?
- MCCONNELL AFB, KS, 67221-9000, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- McConnell AFB
- State?
- Kansas
- Zip?
- 67221
- Country?
- UNITED STATES
Contacts?
- Kevin Smithprimary
- Joshua Kingorisecondary
Description?
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. The purpose of this sources sought is for market research to gain knowledge of potential sources for future needs including interested small business sources. This notice is for planning purposes only. All interested parties should respond. Kansas Air National Guard, McConnell AFB will soon be soliciting for a project for Backflow Preventer Upgrades. The work shall consist of removal of the five backflow preventer systems varying in size and purpose and the installation of five new backflow preventer systems, replacing the existing systems. The contractor will be responsible for removal, proper sizing, connections, installation of the new backflow preventers, testing/certifying, and when complete there will be no defects nor leaks. The project needs to include the following: Building 33, Southwest Bay – 6-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 6-inch diameter Fire Suppression Backflow Prevention System. Install a new 6-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 6-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Description Building 44, Room 122, South wall – 4-inch diameter Backflow Preventer System for Fire Suppression and Double Check Valve Remove the existing 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Install a new 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression and Double Check Valve Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Description Building 44, Room 118, Interior, Southeast wall – 1-inch diameter Backflow Preventer System for Boiler Makeup Remove the existing 1-inch diameter Boiler Makeup Backflow Prevention System. Install a new 1-inch diameter Boiler Makeup Backflow Prevention System. Testing of the newly installed 1-inch diameter Boiler Makeup Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Description Building 48, Room 107, East wall – 4-inch diameter Backflow Preventer System for Fire Suppression Remove the existing 4-inch diameter Fire Suppression Backflow Prevention System. Install a new 4-inch diameter Fire Suppression Backflow Prevention System. Testing of the newly installed 4-inch diameter Fire Suppression Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Description Building 65, Room 154, Interior, South – 2.5-inch diameter Backflow Preventer System for domestic water Remove the existing 2.5-inch diameter domestic water Backflow Prevention System. Install a new 2.5-inch diameter domestic water Backflow Prevention System. Testing of the newly installed 2.5-inch diameter domestic water Backflow Prevention System by a certified installer/tester that meets the requirements set up by the board of appeals of plumbers and gas fitters of the city of Wichita & Sedwick County. Upon completion of the certification of the Backflow Prevention System, provide the 184 CES/CEO with the following: Backflow Prevention System’s Installation Date Backflow Prevention System’s Manufacture Backflow Prevention System’s Model Backflow Prevention System’s Serial Number Backflow Prevention System’s Rebuild Kit Specifications Backflow Prevention System’s Description For this requirement, the small business size standard is $19 million for NAICS 238220. In the event small business In the event small business contractors are not avaialble for adequate competition for this project, it may be advertised as unrestricted. Please advise on your capabilities and or past perfromance in terms of the project requested and respond with a completed sources sought response form. Include the following email subject line "Fire Suppression Backfow Preventer Upgrades" when emailing 184WG.MSG.CONTRACTING@us.af.mil. Use the same address if you have additional questions. Attachments: 1. Statement of Work 2. Sources Sought Response Form
Attachments (2)?
Similar open contracts
Metadata?
- Notice ID?
- 2d64fac728be4aa585ac98144a2b0381
- Full path?
- DEPT OF DEFENSE.DEPT OF THE ARMY.W7M9 USPFO ACTIVITY KSANG 184
- Office code?
- 021.2100.NGB.JFHQ USPFO KS.USPFO KS PROC.W50S7X
- Ingested?
- Jul 10, 2026
- Updated?
- Jul 11, 2026