Eaton Powerware System Replacement

Department of Veterans Affairs · Department of Veterans Affairs

Due Closes in 4 daysRef. 36C24127Q0030

At a glance

What

36C24127Q0030 UPS Eaton Powerware System Replacement - RFIs Does the VA require technicians performing quarterly and annual preventive maintenance to be individually factory-certified or authorized by Eaton?

Industry: Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance (NAICS 811310)

Who can bid
SDVOSB set-aside
Where
Manchester, NH
Key dates
  • Posted: Nov 24, 2026
  • Deadline: Mon, Nov 30, 2026 · 5:00 PM EST (closes in 4 days)
How to respond

Shawn Lawrence · Shawn.Lawrence@va.gov · 914-737-4400 ext. 202121

Submit per the instructions on SAM.gov ↗

Documents
None attached here — check SAM.gov

Description

36C24127Q0030 UPS Eaton Powerware System Replacement - RFIs Does the VA require technicians performing quarterly and annual preventive maintenance to be individually factory-certified or authorized by Eaton? Due to the complex nature of the product and criticality - Yes Will documented experience and technical qualifications satisfy the qualification requirement for routine preventive maintenance? See answer to RFI 1 Is direct access to Eaton's proprietary field-service software mandatory for the prime contractor, or may that requirement be fulfilled through an Eaton-authorized service provider supporting specific procedures? Prime Contractor does not require that; That portion can be filled through an Eaton Authorized Technician.
Read more ↓
Would a contractor be considered technically acceptable if it performs routine maintenance using qualified technicians and subcontracts manufacturer-restricted procedures and startup to Eaton? Yes, minor PM work such as filter changes etc. would be outside the requirement of needing an Eaton Technician. Since Eaton has discontinued the 93E product line, will the VA accept the current Eaton 93PM or another equivalent replacement system meeting the required performance specifications? The VA would accept an Eaton alternative. The goal of the project is to replace existing equipment in-kind with newer model. Does the existing Eaton Powerware 9390 system have an external maintenance bypass (for example, a maintenance bypass panel or a bypass sidecar with maintenance bypass and isolation breakers)? Yes, See photos. Is the replacement expected to include a maintenance bypass sidecar, such as the Eaton 93E 60 kVA bypass sidecar shown in Attachment A, or is it limited to the UPS and Extended Battery Cabinet listed in SOW Section 3.5? The UPS is required to be able to go into maintenance Bypass and maintain power to the computer room during maintenance. What is the kVA rating of the existing unit? The SOW says "Model 80," but the replacement is specified at 60 kVA. Existing UPS is 80KVA. The goal is to replace-in- kind. The 60kVA was utilized as a basis of design. What are the existing input voltage and output voltage? Current system: Eaton Powerware 9390-80 Model 80 AC IN: 208VAC 3W 60Hz 3Phase 240A AC OUT: 208VAC 4W 60Hz 3Phase 222A 78KW 80KVA BYPASS: 208VAC 4W 60Hz 3Phase 222A 80KVA DC: 384-480Vdc 204A Please provide a photo of the existing unit's data plate. See attached photos Please provide photos of the full system (standing back) and of the battery cabinet and batteries. See attached photos Please confirm the battery quantity and model: 40 x Hitachi Chemical Energy Technology 12V 540W, HRC12540WP. Confirmed What is the current battery run time, and what run time is required for the replacement? 60 minutes would it be possible to forward the latest performance specifications/Source Control Drawings for the Powerware System attached Will the VA be paying invoices on a Net-30/45/60 schedule? The VA approves all invoices within 15 days and funds are transferred within 30 days of receipt.

Other notices in this solicitation

All notice detailsShow ↓
Solicitation number
36C24127Q0030
Notice type
Combined Synopsis/Solicitation
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Product/service code (PSC)
J061
Department
Department of Veterans Affairs
Sub-agency
Department of Veterans Affairs
Contracting office
241-NETWORK CONTRACT OFFICE 01 (36C241)
Office location
TOGUS, ME, 04330
Place of performance
Manchester VA Medical Center 718 Smyth Road, Manchester, NH, 03104
Archive date
Jan 29, 2027
Archive type
autocustom
Set-aside code
SDVOSBC
Organization type
OFFICE
Full agency path
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.241-NETWORK CONTRACT OFFICE 01 (36C241)
SAM.gov notice ID
10c3d2d3d0c543179707f8cc9448f701

Contacts