Sources SoughtActiveBuckleySFBChillerReplacement
Buckley SFB Chiller Replacement
DEPT OF DEFENSE / DEPT OF THE AIR FORCE / FA2543 460 CONSKey dates?
- Posted?
- Jul 14, 2026
- Response deadline?
- Jul 22, 2026, 7:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Sources Sought
- Base type?
- Sources Sought
- Set-aside?
- Total Small Business Set-Aside (FAR 19.5)
- Set-aside code?
- SBA
- PSC?
- N041
NAICS?
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE AIR FORCE
- Office?
- FA2543 460 CONS
- Office code?
- 057.5700.FA2543
- Organization type?
- OFFICE
- Office address?
- BUCKLEY AFB, CO, 80011-9572, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Aurora
- State?
- Colorado
- Zip?
- 80011
- Country?
- UNITED STATES
Contacts?
- Ethan Sullivanprimary
Description?
PLEASE SEE ATTACHMENTS FOR ADDITIONAL INFORMATION REGARDING THIS REQUIREMENT Notice Type: Sources Sought (MARKET RESEARCH PURPOSES ONLY) Title: Secure Facility Chilled Water System Replacement – Federal Installation, CO NAICS Code: 238220 – Plumbing, Heating, and Air-Conditioning Contractors Product Service Code (PSC): N041 – Installation of Equipment: Refrigeration, Air Conditioning, and Air Circulating Equipment Response Date: 22 July 2026 Description: The Department of the Air Force (DAF), on behalf of the Base Civil Engineer Squadron (CES) at a Federal Installation in Colorado, is conducting market research to identify qualified, experienced, and interested business sources—specifically targeting small and socio-economic businesses (e.g., 8(a), SDVOSB, HUBZone, WOSB)—capable of performing a complete chilled water system replacement in a 24/7 operations facility. Project Objective: The chilled water system serving the facility's server room currently suffers from degraded serviceability, sub-component failures, and frequent downtime. It is operating at half capacity, which risks the loss of critical cooling for 24/7 operations. The selected contractor must provide all tools, equipment, materials, and certified labor to perform a complete system replacement with zero downtime to the active server room. Key Scope Items & Technical Specifications: Design & Sizing: Perform professional engineering cooling system design load calculations in accordance with UFC 3-410-01 (Sections 2-4 and 2-5.6) to determine final system capacity. Standardization Requirement: In accordance with the DAF Class Justification and Approval (J&A) for HVAC Chiller Replacement Standardization, the design of the new chiller system must be standardized on Trane-series equipment for this installation. Demolition: Safely decommission, recover refrigerant from, and remove the existing degraded chiller (Technical Systems Model: 30A0LM20-PT, Serial: 02-17-125822-001-001) and two existing Computer Room Air Handlers (CRAHs) (Data Aire Model: GFCU-04634, Serials: 2016-3226-A, 20163225-A). Equipment Installation: Procure, install, and commission: One (1) new water chiller with an integrated air-cooled condenser (Trane-series). Two (2) new chilled-water Computer Room Air Handlers (CRAHs) inside the secure server room. Temporary Cooling: Provide continuous, redundant temporary cooling to keep the secure server room strictly within operational temperature limits during the transition phase. Controls Integration: Fully integrate new controls into the base-wide Energy Management Control System (EMCS) in strict compliance with Base EMCS Standards (dated January 21, 2026) and UFC 3-410-02. Logistical & Physical Constraints: Chiller Pad Limits: The new chiller must fit the existing concrete pad (19’ - 11” L x 12’- 8” W x 6” to 8” H) and must not exceed the structural wet weight limit of 12,000 lbs. If the equipment footprint exceeds these limits, the pad must be extended. Rigging & Delivery Clearances: CRAHs must be navigated through a restricted interior corridor with doorway clearances measuring exactly 34” W x 82” H. Electrical: Must integrate with the existing 460V, 60 Hz, 3-Phase power supply and comply with UFC 3-501-01. Security & Clearances: All personnel must pass NCIC background checks, comply with strict OPSEC guidelines, and complete AT Level I training prior to facility access.
Attachments (2)?
Similar open contracts
Metadata?
- Notice ID?
- 0da19958a3d44b0799f019dd2bba01f3
- Full path?
- DEPT OF DEFENSE.DEPT OF THE AIR FORCE.FA2543 460 CONS
- Office code?
- 057.5700.FA2543
- Ingested?
- Jul 15, 2026
- Updated?
- Jul 15, 2026