GovBidAlerts
← My Opportunities
closed🌐 myclearwater17-0048-UT

17-0048-UT East WRF Filter Feed Pump Station & Force Main Improvements

myclearwater / Public Works

Description

The Base Bid Work of this Project generally includes, but is not limited to, improvements to the existing Clearwater East Water Reclamation Facility (WRF) filter feed pump station, specifically consisting of replacement of existing valves, pumps, and their associated appurtenances. The work to modify these components may result in required modifications to the existing valve vault, including demolition and expansion efforts and a bypass of the entire system between clarifier effluent and filter influent. The work also includes relocating existing electrical components onsite to form a new panel and disconnect area, including panels and conduits, and replacing in kind the existing main duty pumps, jockey pumps, associated isolation valves, check valves, and additional ancillary equipment as indicated in the Contract Drawings If existing conditions result in the Base Bid not being practical to be constructed as described, and with the approval of the Owner, a Design Bid Alternate may be considered instead. Documents related to a Design Bid Alternate are included in the Contract Drawings as “DBA” Sheets, and generally describe the option to instead perform the work that generally includes, but is not limited to, demolishing portions of the valve vault and associated piping, fittings, valves, and appurtenances; abandoning portions of the valve vault in place; demolishing indicated discharge piping within the filter feed pump station, and outside through to the discharge header where indicated on the Contract Drawings; and installing new discharge piping, valves, fittings, concrete pad, supports, and appurtenances as required to bring the piping above grade and connect the existing filter feed pump station to the existing filter feed force main at a single location. All other elements of the base bid outside the piping, fittings, valves, appurtenances, and valve vault shall still apply (e.g. electrical infrastructure movement, etc.). The Contractor shall provide copies of a current Contractor License/Registration with the state of Florida and Pinellas County in the bid response. The Contractor shall provide Fixed project signs as described in Section III, Section 23 of the Contract Documents. The final number of project signs will be determined at the beginning of the project based on the Contractor’s schedule of work submitted for approval. Additional project signs may be required at no additional cost to the city due to the Contractor’s schedule of work. Contract Period: 365 Consecutive Calendar Days

Details

Posted
Mar 25, 2026
Response deadline
Apr 29, 2026, 6:00 PM UTC
Status
closed
Buyer
myclearwater
Department
Public Works
Jurisdiction
myclearwater
Reference #
17-0048-UT
Summary
<div><p>The Base Bid Work of this Project generally includes, but is not limited to, improvements to the existing Clearwater East Water Reclamation Facility (WRF) filter feed pump station, specificall
Is Paused
false
Template Title
Construction Bid
Copy Count
0
Government Organization City
Clearwater
Government Organization Name
City of Clearwater
Government Organization State
FL
Government Organization Website
www.myclearwater.com
Government Organization Zip Code
33756
Government Organization Address1
100 South Myrtle Avenue
Government Organization Timezone
America/New_York
Government Organization Country Code
US
Government Organization Phone Country
1
Closed Substatus
awarded

Contact

(727)562-4842
Finding similar opportunities…

This listing is a summary from myclearwater's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.

Raw record
{
  "id": 238062,
  "_slug": "myclearwater",
  "title": "17-0048-UT East WRF Filter Feed Pump Station & Force Main Improvements",
  "status": "closed",
  "summary": "<div><p>The Base Bid Work of this Project generally includes, but is not limited to, improvements to the existing Clearwater East Water Reclamation Facility (WRF) filter feed pump station, specifically consisting of replacement of existing valves, pumps, and their associated appurtenances. The work to modify these components may result in required modifications to the existing valve vault, including demolition and expansion efforts and a bypass of the entire system between clarifier effluent and filter influent. The work also includes relocating existing electrical components onsite to form a new panel and disconnect area, including panels and conduits, and replacing in kind the existing main duty pumps, jockey pumps, associated isolation valves, check valves, and additional ancillary equipment as indicated in the Contract Drawings</p><p>If existing conditions result in the Base Bid not being practical to be constructed as described, and with the approval of the Owner, a Design Bid Alternate may be considered instead. Documents related to a Design Bid Alternate are included in the Contract Drawings as &ldquo;DBA&rdquo; Sheets, and generally describe the option to instead perform the work that generally includes, but is not limited to, demolishing portions of the valve vault and associated piping, fittings, valves, and appurtenances; abandoning portions of the valve vault in place; demolishing indicated discharge piping within the filter feed pump station, and outside through to the discharge header where indicated on the Contract Drawings; and installing new discharge piping, valves, fittings, concrete pad, supports, and appurtenances as required to bring the piping above grade and connect the existing filter feed pump station to the existing filter feed force main at a single location. All other elements of the base bid outside the piping, fittings, valves, appurtenances, and valve vault shall still apply (e.g. electrical infrastructure movement, etc.).</p></div><div><p data-ccp-padding-top=\"0px\" data-ccp-border-top=\"0.6666666666666666px solid #000000\"><span xml:lang=\"EN-US\" data-contrast=\"auto\">The Contractor shall provide copies of a current Contractor License/Registration with the state of Florida&nbsp;and&nbsp;Pinellas County in the bid response.</span></p><div><p data-ccp-padding-bottom=\"1.3333333333333333px\" data-ccp-border-bottom=\"0.6666666666666666px solid #000000\"><span xml:lang=\"EN-US\" data-contrast=\"auto\">The Contractor shall provide&nbsp;Fixed&nbsp;project signs as described in Section III,&nbsp;Section&nbsp;23 of the Contract Documents. The final number of project signs will be&nbsp;determined&nbsp;at the beginning of the project based on the Contractor&rsquo;s schedule of work&nbsp;submitted&nbsp;for approval.&nbsp;Additional&nbsp;project signs may be&nbsp;required&nbsp;at no&nbsp;additional&nbsp;cost to the&nbsp;city&nbsp;due to the Contractor&rsquo;s schedule of work.</span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:6,&quot;335551620&quot;:6,&quot;335559738&quot;:120,&quot;335559739&quot;:0,&quot;335559740&quot;:240,&quot;335572071&quot;:4,&quot;335572072&quot;:0,&quot;335572073&quot;:0,&quot;335572075&quot;:4,&quot;335572076&quot;:4,&quot;335572077&quot;:0,&quot;335572079&quot;:4,&quot;335572080&quot;:1,&quot;335572081&quot;:0,&quot;335572083&quot;:4,&quot;335572084&quot;:4,&quot;335572085&quot;:0,&quot;469789798&quot;:&quot;single&quot;,&quot;469789802&quot;:&quot;single&quot;,&quot;469789806&quot;:&quot;single&quot;,&quot;469789810&quot;:&quot;single&quot;}\">&nbsp;</span></p></div><div><p data-ccp-padding-top=\"0px\" data-ccp-border-top=\"0.6666666666666666px solid #000000\"><span xml:lang=\"EN-US\" data-contrast=\"auto\">Contract Period:&nbsp;365&nbsp;Consecutive&nbsp;Calendar Days</span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335551550&quot;:2,&quot;335551620&quot;:2,&quot;335559738&quot;:120,&quot;335559739&quot;:0,&quot;335559740&quot;:240,&quot;335572071&quot;:4,&quot;335572072&quot;:0,&quot;335572073&quot;:0,&quot;335572075&quot;:4,&quot;335572076&quot;:4,&quot;335572077&quot;:0,&quot;335572079&quot;:4,&quot;335572080&quot;:1,&quot;335572081&quot;:0,&quot;335572083&quot;:4,&quot;335572084&quot;:4,&quot;335572085&quot;:0,&quot;469789798&quot;:&quot;single&quot;,&quot;469789802&quot;:&quot;single&quot;,&quot;469789806&quot;:&quot;single&quot;,&quot;469789810&quot;:&quot;single&quot;}\">&nbsp;</span></p></div></div>",
  "isPaused": false,
  "template": {
    "title": "Construction Bid"
  },
  "addendums": [
    {
      "id": 112652
    }
  ],
  "copyCount": 0,
  "isPrivate": false,
  "comingSoon": false,
  "created_at": "2026-02-17T17:41:54.231Z",
  "department": {
    "id": 8185,
    "name": "Public Works"
  },
  "government": {
    "code": "myclearwater",
    "organization": {
      "city": "Clearwater",
      "logo": "https://assets.procurement.opengov.com/logo-uploads/fcf43a5e-fefc-43a8-8466-c79f5ac65c9f_TinyTake03-06-2024-08-22-53.png",
      "name": "City of Clearwater",
      "phone": "(727)562-4842",
      "state": "FL",
      "website": "www.myclearwater.com",
      "zipCode": "33756",
      "address1": "100 South Myrtle Avenue",
      "address2": null,
      "phoneExt": null,
      "timezone": "America/New_York",
      "countryCode": "US",
      "phoneCountry": "1"
    }
  },
  "financialId": "17-0048-UT",
  "closeOutReason": null,
  "closedSubstatus": "awarded",
  "proposalDeadline": "2026-04-29T18:00:00.000Z",
  "releaseProjectDate": "2026-03-25T04:00:00.000Z"
}