GovBidAlerts
← My Opportunities
Tenderopen🌐 MKD796326-2026

North Macedonia – Angiography supplies – Procurement of goods – dispensable material for endovascular procedures on the peripheral vascular system

Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid

Description

-Z-Cell design with radiopaque markers on both ends of the stent - an ergonomic handle for positioning (single-hand stent deployment) - an internal port for rinsing - compatible with 0.035” wire and 6F introducer - stent length: 40-120mm - diameter: 5-8mm - catheter length: 80cm or 125cm - the system shall be placed on a triaxial catheter for precise placement, with a working length of 130 cm - compatible with 0.035” (0.89 mm) guide wire and introducers with a maximum of 6F for all dimensions - stent diameters of 6mm and 7 mm - stent length: from 40 - 120 mm - the drug dose should not be more than 0.200 µg/mm² - the drug shall be released from the device surface in order to have a local effect on the tissue, and to reach a therapeutic concentration in a period of at least 12 months - Rx system - compatible with 5F introducer sheath - diameter: 5-10mm - stent length: 16-40 mm - a possibility for reposition during expansion of up to 50% - the stent diameter shall adapt to the tapered shape of the carotid artery - there shall be a possibility of repositioning the wire up to 50% of the initial placement, allowing precise stent placement - to have a closed design that provides an increased protection for covering the lesion, plaque control, angiographic results and embolic protection during device removal - available in diameters from 5 mm to 9 mm, length from 30 mm to 50 mm - catheter length: 135 cm - OTW technique - biomimetric - diameter: 4.5-6.5 mm - stent length: 20-200 mm - 6F compatible - catheter length: 120 cm maximum - compatible with 6F introducer sheath and 0.018” wire - Rx system - diameter: 5-8mm - stent length from 40 to 155 mm - system length: 80 and 140 cm - 2 radiopaque markers - flexible with high radial strength - strut thickness: 125–150 μm - dimensions: diameter 5–10 mm, length 18–58 mm - tip profile: 0.036'' - manufactured using nitinol technology with a hybrid design, featuring an open-cell geometry in the central section for flexibility and a closed-cell design at the ends for precise placement - the distal and proximal sections should incorporate radiopaque markers for improved visualization - available in diameters from 6 to 12 mm and lengths from 20 to 120 mm - the system should have lengths of 75 cm and 120 cm and an ergonomic handle allowing gradual or rapid deployment - delivery system featuring a three-layer catheter with 2 radiopaque markers - working length: 80 cm and 130 cm - compatible with a 6F introducer sheath and a 0.035” wire - dimensions: diameter 5–10 mm length 40–200 mm - Straight and tapered configuration - with a so-called closed cell design - RX technique - diameter 6-10mm and length 20-40mm - compatible with 6F guiding introducer - stainless steel - with a so-called open cell design - radiopaque markers on both ends of the stent and balloon catheter - the stent shall be placed on a balloon catheter with a length of 80-135cm - the stent shall be based on the OTW system, compatible with a guide wire 0.035” - stent diameter: 5-10mm - compatible with 6-7F introducers - stent length: from 12mm or less, to 57 mm or more - OTW system - struts thickness: 110μm (5-7mm) - with PROBIO coating (amоrphous silicon carbidе) - compatible with a 0.035" guide wire - on a carrier available in lengths of 90,135 and 170cm - stent length: 18 - 78mm - diameter: 5-10mm - with a so-called open cell design - equipped with a single-hand ergonomic system for placement with a triaxial design with a mechanism for accurate stent positioning -OTW technique - compatible with 5F introducer and 0.035" guide wire - catheter length: 80cm-150cm - stent diameter: 5-8mm - stent length: 20-150mm and longer - OTW technique - catheter length: 50cm-150cm+/-5% - balloon length from 2cm to 12cm, or longer - inflatable balloon with a diameter from 1.5mm to 3mm, or larger - burst pressure:16atm+/-5% - accepts 0.014“ guide wire - compatible with a “sheath“ of 3F - shall be indicated for carotid, coronary, and peripheral interventional procedures - the system shall allow independent movement of the wire and enable longitudinal and rotational movement of the filter - to include an option to fracture the wire and use the remaining portion as the primary guide wire through the catheter based on the RX technique - filter dimension: 3-7mm - wire length: 320/190cm (+/-5cm), compatible with a guide wire with a diameter of 0.014-0.018" and 5F introducer - compatible with 6F catheter, length 190 cm and 300 cm - MR 0.014 system - profile: 3.2 F (1.1mm) - nitinol filter loop - over-the-wire (OTW) - 0.035'' compatible - diameter 4.00-12.00mm, in 1 mm increments - length: 40-60-80-120-150, 200, 250mm - compatible with 5-6-7-9F introducer - catheter length: 80 and 130cm (for all available balloon sizes) - ОТW technique - compatible with 0.035’’ wires - balloon diameter: 4.0-8.0mm - length: 20.0mm - 80.0 mm, or longer - compatible with 5-7F introducers - nominal pressure: 10bar+/-5% - ОТW technique - hydrophilic coating - “dual lumen shaft“ - compatible with 0.035’’ wires - balloon diameter: 3.0-12.0mm - length: 20.0-300.0 mm - compatible with 5-7F introducers - catheter length: 80cm,130cm - a balloon catheter made of material that provides both trackability and high-pressure within the same balloon - compatible with 5F (1.67 mm) introducers for balloons up to 7 mm, и 6F (2.00 mm) for balloons up to 10 mm - available in balloon lengths from 20mm to 200 mm, diameters from 3 mm to 12 mm and catheter length of 75 cm and 135 cm - ablation active zone length: 3cm, 7cm or 8cm - catheter working length: 60-100cm - with depth markers - with a 0.025“ guide wire lumen - 6 и 7F - with a nitinol guide wire with a platinum tip, with a diameter of 0.018 “and length 40cm+/-5% - introducer with: inner diameter of 2.9F, outer diameter from 4.0 to 5.0F, and length 7cm ±5% - echogenic needle 21G, length 4 cm (+/-5%) and echogenic tip - “Check-flow“ valve - catheter of 2.3-2.6F that can be inserted through 4F catheter with length from 65cm to 150cm - accepts guide wire with a diameter from 0.014“ to 0.018“ - platinum and iridium markers - with either a curved or straight tip - length: 40-135cm - infusion length: 5-50cm - diameter: 4-5F - compatible with 0.035-0.038" guide wire - with a double inner mesh and 3 radiopaque markers positioned at 4 and 6cm from the tip for precise lesion measurement and stent or balloon positioning - diameter: 4F - compatible with 0.035” wire - length: 150cm (+/-5%) - with straight or 30º curved tip - OTW system (for OTW technique) - compatible with 0.018“ wire - balloon diameter: from 2-7 mm, or larger - balloon length: from 40-120 mm, or longer - guiding catheters length: 90-150cm - compatible with 4F and 5F -- with lesion entry profile of 0.020" (0.51 mm) - deflation time: 10 seconds - available in diameters from 2 to 8 mm - lengths from 40 to 200 mm and - shaft lengths of 90, 135 и 150 cm - catheter length of 90, 130 и 170 cm - balloon diameter: 3 -12 mm - with various balloon lengths from 20 to 250mm - with two markers - compatible with 5F, 6F and 7F introducer - made of Pebax semi-compliant balloon material with hydrophilic coating or equivalent - the tip is tapered, with a lesion entry profile not larger than 0.020” (0.51 mm) - deflation time: maximum 10 seconds - balloon diameter from 2.0 mm to 10.0 mm and length from 10 mm to 220 mm - the catheter shall be available with shaft lengths from 90 cm to 150 cm - compatible with 5F introducer - suitable for broad clinical applications, including carotid and post-stent interventions The set shall contain: - 5 cc vial with adhesive - 5F delivery catheter with a minimum length of 91cm - two laser markers for high echogenic visibility - 7F introducer with a minimum length of 80cm - 5F dilator with a minimum length of 87cm - applicator with an ergonomic pistol-shaped handle, allowing controlled release of 0.10cc adhesive during application - 0.035" guide wire with J-tip - two 3cc syringes - tubing length: minimum 2m - the tubing shall be made of PVC with a silicone section for the infusion roller pump - one side of the tubing shall end with an integrated luer lock- connector and spike-connector with port on the other side -the set shall include an adjustable safety clamp to open/close fluid flow - an integrated connector for easy attachment of the tubing to the fluid bottle - an integrated valve for fluid release - catheter length: 90,150,200 cm - balloon diameter: 1.5 mm to 6.0 mm - balloon length: 20-240 mm - compatible with 4-6F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm - catheter length: 75,135,200 cm - balloon diameter: 3 to 7.0 mm - balloon length: 20-240 mm - compatible with 5-7F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm - with length up to 110 cm, straight tip - with an outer diameter of 6F - with an inner diameter of at least 2.21mm - PTFE inner lining - with Tuohy-Borst Sidearm valve and dilator with length of 122/102cm - compatible with 0.038” wire - length range: 45–90 cm - outer diameter: 5F–8F - with either a straight or curved tip - hydrophilic coating from 5 to 35 cm on the distal end - with a Tuohy-Borst Sidearm and a Cross-cut valve - compatible with a 0.038” wire - embolic protection filter with dimensions of 5 and 7.2mm and pores of at least 120 microns - the system includes a collection catheter - the entire system is compatible with 5F introducer or 6F guiding catheter - RX (rapid exchange) - diameter range from 4.0 to 7.0mm - length from 15 to 40mm - shaft length: 80-135cm - compatible with 6F guiding catheter - RBP 14atm for all sizes - the system shall provide rotational, frontal, and expandable cutting with blades rotating at approximately 70,000 rotations per minute - to have a minimum of five frontal blades for initial lesion engagement and treatment of stenotic or occluded vessels - to use an “up/down” blade technology to allow flexibility for treating multiple vessel diameters with a single catheter - to include active and continuous mechanical aspiration to remove thrombus and debris, reducing the risk of distal embolization and ensuring optimal debulking - the cutting mechanism shall be differential, selectively removing the diseased, non-elastic tissue from the healthy vascular tissue that needs to remain protected - the catheter shall contain internal lumens for infusion, aspiration, and guide wire navigation, as well as external ports for solution and aspiration - the catheter length shall be 120 cm, 135 cm or 145 cm, depending on configuration - all variants shall be compatible with 7 F introducer and 0.014” guide wire - two embedded Platinum-iridium markers - compatible with 5-6F introducer - balloon diameter: 2-7mm - balloon length: 40,60,80,120,150mm - catheter length: 85 and 150cm for all available balloon sizes - max guide wire 0.018'' - inflation time of at least 30 secunds - Paclitaxel drug dose: 3.0 μg/mm2 - OTW system - compatible with 0.018'' wire - balloon diameter from 2-7mm - balloon length: 40-150mm - length of the guiding catheters: 135cm - compatible with 5F-7F introducers - minimum 15 cm of radiopacity at the tip - tapered tip from 0.008 to 0.013” - tip load: 20, 30, and 40 g - single-core design - length: 180–300 cm - the set should consist of three snares made of nitinol and platinum, and a catheter with a radiopaque marker - the snare should have a diameter from 6 to 45 mm and overall length of 120 and 175 cm - the catheter should be 3.2, 6, and 7F, with length of 100 and 150 cm - the set should include a torque device - introducer length: 10 cm - introducer outer diameter: 4F - nitinol guide wire (0.018”) length: 40 cm - 21G needle with an echogenic tip and a length of 7 cm - palladium tip - five emitters - diameter from 3.5 to 8.0 mm - length: 60 mm - 30 pulses in 10 cycles - catheter working length: 135 cm - compatible with a 6F introducer for diameters from 3.5 to 7.0 mm, and - compatible with a 7F introducer for an 8.0 mm diameter - the catheters should be supplied with a protective sleeve to cover the cable connection between the generator and the catheter - the distal section should have a hydrophilic coating to facilitate insertion and improve navigation through blood vessels - to be radiopaque along its entire length and feature a radiopaque marker positioned approximately 5 mm from the distal tip for precise fluoroscopic visualization - to incorporate an integrated hemostatic valve to minimize blood loss during the procedure - lengths: at least 45 cm, 65 cm, and 90 cm - sizes: at least 4F to 8F - with various tip configurations: Straight, Multipurpose, Hockey Stick, and Renal Double Curve - compatible with 0.018” and/or 0.035”/0.038” guide wires, depending on sheath size The set should include a guide sheath introducer, dilator, and adapter with a hemostatic valve. It should be non-pyrogenic, latex-free, and individually sterile packaged. - catheter lengths: 80, 100, 140, and 150 cm - 2 tungsten radiopaque markers - compatible with 4, 5, and 6F introducer and 0.014”-0.035” wires - nominal pressure: 6–7 atm - RBP: 14–16 atm - dimensions: diameter 1.5–8 mm and length 20–200 mm -- catheter length: 80, 140, and 200 cm - coated with a silicone layer - 2 radiopaque markers - tip profile: 0.036” - crossing profile: 0.057”–0.083” -OTW technique - 0.018” compatible - minimum diameter range: 4.00–7.00 mm, in 1 mm increments - length: 40, 60, 80, 120, and 150 mm - compatible with 5F introducer - catheter length: 80 and 130 cm for all available balloon sizes

Documents (1)

  • 📎 download
    text/html · 31 KB
    Download

Details

Posted
Nov 16, 2026
Response deadline
Dec 15, 2026, 10:59 PM UTC (29d)
Type
Tender
Category
33111710
Status
open
Estimated value
EUR 390,244
Buyer
Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid
Jurisdiction
MKD
Reference #
796326-2026
Has Description
true
Country
MKD
Tw Mul
Ohrid
Sub Lg
MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD,
Tv Cur
EUR
Deadline
2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T
Form
competition
Ojs
222/2026
Eu
no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu
Legal
32014L0024
Notice
cn-social
Total
390244
Quantity
5, 9, 25, 5, 12, 12, 5, 5, 13, 25, 15, 5, 13, 25, 50, 3, 27, 15, 30, 20, 100, 5, 20, 10, 60, 10, 20, 10, 25, 2, 30, 25, 30, 10, 65, 15, 20, 10, 47, 10, 6, 1, 1, 5, 25, 25, 45, 5
Dispatch
Nov 13, 2026
Dps
none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, no
Identifier
LOT-0001, LOT-0002, LOT-0003, LOT-0004, LOT-0005, LOT-0006, LOT-0007, LOT-0008, LOT-0009, LOT-0010, LOT-0011, LOT-0012, LOT-0013, LOT-0014, LOT-0015, LOT-0016, LOT-0017, LOT-0018, LOT-0019, LOT-0020,
Recurrence
false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, fals
Contract
supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies,
Publication
2026-11-16+01:00
Accessibility
n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-in
Official
ENG
Classification
33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710,
Procedure
The subject of the agreement consists of 48 separate parts
Estimated
7967, 14560, 18699, 5609, 7414, 9365, 2276, 2243, 8032, 15040, 8536, 1617, 3008, 6052, 31024, 1682, 19021, 1707, 3956, 2764, 36260, 557, 6683, 1056, 5902, 6008, 1121, 1088, 3455, 1600, 975, 4471, 5365
Variant
not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-a
Place
MK003, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD
Provided
ted-esen, serv-prov
Electronic
true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, tr
Organisation
+38946277201
Reserved
no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no
Public
2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 20
Award
price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, pric
Internal
02-817
Selection
epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-do
Procurement
02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02
Main
cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv,
Exclusion
epo-procurement-document
Tender
DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY,
Guarantee
The contracting party shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of t
Other
Aa: pub-undert · Bi: 4087445 · Dt: 2026-12-15T12:00:00+01:00, 2026-12-15T12:00:00+01:00, 2026-12-15T12:00:00+01:00, 2026-12-15T12:00:00 · Ia: https://www.cardioohrid.mk/ · Nl: 48 · Bt 14 Lot: non-restricted-document, non-restricted-document, non-restricted-document, non-restricted-document, · Bt 17 Lot: required, required, required, required, required, required, required, required, required, required, · Bt 21 Lot Eng: A peripheral self-expanding nitinol stent coated with a drug from the family Taxani directly on the · Bt 24 Lot Eng: -Z-Cell design with radiopaque markers on both ends of the stent - an ergonomic handle for positioni · Bt 122 Lot Eng: In order to participate in the electronic auction, it is necessary to register in the Electronic Sys · Bt 538 Lot: UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, UNKNOWN, U · Bt 625 Lot: H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, H87, · Bt 727 Lot: anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, anyw-cou, · Bt 743 Lot: allowed, allowed, allowed, allowed, allowed, allowed, allowed, allowed, allowed, allowed, allowed, a · Bt 04 Notice: d50443c3-2b8e-4655-871a-db79b086d60a · Bt 13(D) Lot: 2026-12-09+01:00, 2026-12-09+01:00, 2026-12-09+01:00, 2026-12-09+01:00, 2026-12-09+01:00, 2026-12-09 · Bt 13(T) Lot: 12:00:00+01:00, 12:00:00+01:00, 12:00:00+01:00, 12:00:00+01:00, 12:00:00+01:00, 12:00:00+01:00, 12:0 · Bt 132(T) Lot: 00:00:00+01:00, 00:00:00+01:00, 00:00:00+01:00, 00:00:00+01:00, 00:00:00+01:00, 00:00:00+01:00, 00:0 · Bt 701 Notice: 4e507c86-e9b8-4f4b-b5d8-cde82af525a3 · Bt 757 Notice: 1 · Opp 070 Notice: 20 · Opt 002 Notice: eforms-sdk-1.14 · Bt 05(B) Notice: 07:46:51Z · Bt 21 Procedure Eng: Procurement of goods – dispensable material for endovascular procedures on the peripheral vascular s · Bt 23 Procedure: supplies · Bt 634 Procedure: false · Bt 5071 Procedure: MK003 · Opa 98 Lot Number: 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, 90, · Bt 26(M) Procedure: cpv · Bt 5101(A) Procedure: Settlement “St. Stefan” b.b. – Ohrid · Bt 508 Procedure Buyer: https://e-nabavki.gov.mk

Contact

Similar open opportunities

See opportunities like this one

GovBidAlerts matches this solicitation to similar open bids across 114,000+ open bids from 2,500+ sources. Create a free account to unlock them.

Create free accountno credit card required

This listing is a summary from MKD's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.