Tenderopen🌐 MKD796326-2026
North Macedonia – Angiography supplies – Procurement of goods – dispensable material for endovascular procedures on the peripheral vascular system
Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid
Description
-Z-Cell design with radiopaque markers on both ends of the stent - an ergonomic handle for positioning (single-hand stent deployment) - an internal port for rinsing - compatible with 0.035” wire and 6F introducer - stent length: 40-120mm - diameter: 5-8mm - catheter length: 80cm or 125cm
- the system shall be placed on a triaxial catheter for precise placement, with a working length of 130 cm - compatible with 0.035” (0.89 mm) guide wire and introducers with a maximum of 6F for all dimensions - stent diameters of 6mm and 7 mm - stent length: from 40 - 120 mm - the drug dose should not be more than 0.200 µg/mm² - the drug shall be released from the device surface in order to have a local effect on the tissue, and to reach a therapeutic concentration in a period of at least 12 months
- Rx system - compatible with 5F introducer sheath - diameter: 5-10mm - stent length: 16-40 mm - a possibility for reposition during expansion of up to 50%
- the stent diameter shall adapt to the tapered shape of the carotid artery - there shall be a possibility of repositioning the wire up to 50% of the initial placement, allowing precise stent placement - to have a closed design that provides an increased protection for covering the lesion, plaque control, angiographic results and embolic protection during device removal - available in diameters from 5 mm to 9 mm, length from 30 mm to 50 mm - catheter length: 135 cm
- OTW technique - biomimetric - diameter: 4.5-6.5 mm - stent length: 20-200 mm - 6F compatible - catheter length: 120 cm maximum
- compatible with 6F introducer sheath and 0.018” wire - Rx system - diameter: 5-8mm - stent length from 40 to 155 mm
- system length: 80 and 140 cm - 2 radiopaque markers - flexible with high radial strength - strut thickness: 125–150 μm - dimensions: diameter 5–10 mm, length 18–58 mm - tip profile: 0.036''
- manufactured using nitinol technology with a hybrid design, featuring an open-cell geometry in the central section for flexibility and a closed-cell design at the ends for precise placement - the distal and proximal sections should incorporate radiopaque markers for improved visualization - available in diameters from 6 to 12 mm and lengths from 20 to 120 mm - the system should have lengths of 75 cm and 120 cm and an ergonomic handle allowing gradual or rapid deployment
- delivery system featuring a three-layer catheter with 2 radiopaque markers - working length: 80 cm and 130 cm - compatible with a 6F introducer sheath and a 0.035” wire - dimensions: diameter 5–10 mm length 40–200 mm
- Straight and tapered configuration - with a so-called closed cell design - RX technique - diameter 6-10mm and length 20-40mm - compatible with 6F guiding introducer
- stainless steel - with a so-called open cell design - radiopaque markers on both ends of the stent and balloon catheter - the stent shall be placed on a balloon catheter with a length of 80-135cm - the stent shall be based on the OTW system, compatible with a guide wire 0.035” - stent diameter: 5-10mm - compatible with 6-7F introducers - stent length: from 12mm or less, to 57 mm or more
- OTW system - struts thickness: 110μm (5-7mm) - with PROBIO coating (amоrphous silicon carbidе) - compatible with a 0.035" guide wire - on a carrier available in lengths of 90,135 and 170cm - stent length: 18 - 78mm - diameter: 5-10mm
- with a so-called open cell design - equipped with a single-hand ergonomic system for placement with a triaxial design with a mechanism for accurate stent positioning -OTW technique - compatible with 5F introducer and 0.035" guide wire - catheter length: 80cm-150cm - stent diameter: 5-8mm - stent length: 20-150mm and longer
- OTW technique - catheter length: 50cm-150cm+/-5% - balloon length from 2cm to 12cm, or longer - inflatable balloon with a diameter from 1.5mm to 3mm, or larger - burst pressure:16atm+/-5% - accepts 0.014“ guide wire - compatible with a “sheath“ of 3F
- shall be indicated for carotid, coronary, and peripheral interventional procedures - the system shall allow independent movement of the wire and enable longitudinal and rotational movement of the filter - to include an option to fracture the wire and use the remaining portion as the primary guide wire through the catheter based on the RX technique - filter dimension: 3-7mm - wire length: 320/190cm (+/-5cm), compatible with a guide wire with a diameter of 0.014-0.018" and 5F introducer
- compatible with 6F catheter, length 190 cm and 300 cm - MR 0.014 system - profile: 3.2 F (1.1mm) - nitinol filter loop
- over-the-wire (OTW) - 0.035'' compatible - diameter 4.00-12.00mm, in 1 mm increments - length: 40-60-80-120-150, 200, 250mm - compatible with 5-6-7-9F introducer - catheter length: 80 and 130cm (for all available balloon sizes)
- ОТW technique - compatible with 0.035’’ wires - balloon diameter: 4.0-8.0mm - length: 20.0mm - 80.0 mm, or longer - compatible with 5-7F introducers - nominal pressure: 10bar+/-5%
- ОТW technique - hydrophilic coating - “dual lumen shaft“ - compatible with 0.035’’ wires - balloon diameter: 3.0-12.0mm - length: 20.0-300.0 mm - compatible with 5-7F introducers - catheter length: 80cm,130cm
- a balloon catheter made of material that provides both trackability and high-pressure within the same balloon - compatible with 5F (1.67 mm) introducers for balloons up to 7 mm, и 6F (2.00 mm) for balloons up to 10 mm - available in balloon lengths from 20mm to 200 mm, diameters from 3 mm to 12 mm and catheter length of 75 cm and 135 cm
- ablation active zone length: 3cm, 7cm or 8cm - catheter working length: 60-100cm - with depth markers - with a 0.025“ guide wire lumen - 6 и 7F
- with a nitinol guide wire with a platinum tip, with a diameter of 0.018 “and length 40cm+/-5% - introducer with: inner diameter of 2.9F, outer diameter from 4.0 to 5.0F, and length 7cm ±5% - echogenic needle 21G, length 4 cm (+/-5%) and echogenic tip - “Check-flow“ valve
- catheter of 2.3-2.6F that can be inserted through 4F catheter with length from 65cm to 150cm - accepts guide wire with a diameter from 0.014“ to 0.018“ - platinum and iridium markers - with either a curved or straight tip
- length: 40-135cm - infusion length: 5-50cm - diameter: 4-5F - compatible with 0.035-0.038" guide wire
- with a double inner mesh and 3 radiopaque markers positioned at 4 and 6cm from the tip for precise lesion measurement and stent or balloon positioning - diameter: 4F - compatible with 0.035” wire - length: 150cm (+/-5%) - with straight or 30º curved tip
- OTW system (for OTW technique) - compatible with 0.018“ wire - balloon diameter: from 2-7 mm, or larger - balloon length: from 40-120 mm, or longer - guiding catheters length: 90-150cm - compatible with 4F and 5F
-- with lesion entry profile of 0.020" (0.51 mm) - deflation time: 10 seconds - available in diameters from 2 to 8 mm - lengths from 40 to 200 mm and - shaft lengths of 90, 135 и 150 cm
- catheter length of 90, 130 и 170 cm - balloon diameter: 3 -12 mm - with various balloon lengths from 20 to 250mm - with two markers - compatible with 5F, 6F and 7F introducer
- made of Pebax semi-compliant balloon material with hydrophilic coating or equivalent - the tip is tapered, with a lesion entry profile not larger than 0.020” (0.51 mm) - deflation time: maximum 10 seconds - balloon diameter from 2.0 mm to 10.0 mm and length from 10 mm to 220 mm - the catheter shall be available with shaft lengths from 90 cm to 150 cm - compatible with 5F introducer - suitable for broad clinical applications, including carotid and post-stent interventions
The set shall contain: - 5 cc vial with adhesive - 5F delivery catheter with a minimum length of 91cm - two laser markers for high echogenic visibility - 7F introducer with a minimum length of 80cm - 5F dilator with a minimum length of 87cm - applicator with an ergonomic pistol-shaped handle, allowing controlled release of 0.10cc adhesive during application - 0.035" guide wire with J-tip - two 3cc syringes
- tubing length: minimum 2m - the tubing shall be made of PVC with a silicone section for the infusion roller pump - one side of the tubing shall end with an integrated luer lock- connector and spike-connector with port on the other side -the set shall include an adjustable safety clamp to open/close fluid flow - an integrated connector for easy attachment of the tubing to the fluid bottle - an integrated valve for fluid release
- catheter length: 90,150,200 cm - balloon diameter: 1.5 mm to 6.0 mm - balloon length: 20-240 mm - compatible with 4-6F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm
- catheter length: 75,135,200 cm - balloon diameter: 3 to 7.0 mm - balloon length: 20-240 mm - compatible with 5-7F introducer - with 2 radiopaque markers (20-150mm) and 4 (180-240mm) - NP 12atm
- with length up to 110 cm, straight tip - with an outer diameter of 6F - with an inner diameter of at least 2.21mm - PTFE inner lining - with Tuohy-Borst Sidearm valve and dilator with length of 122/102cm - compatible with 0.038” wire
- length range: 45–90 cm - outer diameter: 5F–8F - with either a straight or curved tip - hydrophilic coating from 5 to 35 cm on the distal end - with a Tuohy-Borst Sidearm and a Cross-cut valve - compatible with a 0.038” wire
- embolic protection filter with dimensions of 5 and 7.2mm and pores of at least 120 microns - the system includes a collection catheter - the entire system is compatible with 5F introducer or 6F guiding catheter
- RX (rapid exchange) - diameter range from 4.0 to 7.0mm - length from 15 to 40mm - shaft length: 80-135cm - compatible with 6F guiding catheter - RBP 14atm for all sizes
- the system shall provide rotational, frontal, and expandable cutting with blades rotating at approximately 70,000 rotations per minute - to have a minimum of five frontal blades for initial lesion engagement and treatment of stenotic or occluded vessels - to use an “up/down” blade technology to allow flexibility for treating multiple vessel diameters with a single catheter - to include active and continuous mechanical aspiration to remove thrombus and debris, reducing the risk of distal embolization and ensuring optimal debulking - the cutting mechanism shall be differential, selectively removing the diseased, non-elastic tissue from the healthy vascular tissue that needs to remain protected - the catheter shall contain internal lumens for infusion, aspiration, and guide wire navigation, as well as external ports for solution and aspiration - the catheter length shall be 120 cm, 135 cm or 145 cm, depending on configuration - all variants shall be compatible with 7 F introducer and 0.014” guide wire
- two embedded Platinum-iridium markers - compatible with 5-6F introducer - balloon diameter: 2-7mm - balloon length: 40,60,80,120,150mm - catheter length: 85 and 150cm for all available balloon sizes - max guide wire 0.018'' - inflation time of at least 30 secunds - Paclitaxel drug dose: 3.0 μg/mm2
- OTW system - compatible with 0.018'' wire - balloon diameter from 2-7mm - balloon length: 40-150mm - length of the guiding catheters: 135cm - compatible with 5F-7F introducers
- minimum 15 cm of radiopacity at the tip - tapered tip from 0.008 to 0.013” - tip load: 20, 30, and 40 g - single-core design - length: 180–300 cm
- the set should consist of three snares made of nitinol and platinum, and a catheter with a radiopaque marker - the snare should have a diameter from 6 to 45 mm and overall length of 120 and 175 cm - the catheter should be 3.2, 6, and 7F, with length of 100 and 150 cm - the set should include a torque device
- introducer length: 10 cm - introducer outer diameter: 4F - nitinol guide wire (0.018”) length: 40 cm - 21G needle with an echogenic tip and a length of 7 cm - palladium tip
- five emitters - diameter from 3.5 to 8.0 mm - length: 60 mm - 30 pulses in 10 cycles - catheter working length: 135 cm - compatible with a 6F introducer for diameters from 3.5 to 7.0 mm, and - compatible with a 7F introducer for an 8.0 mm diameter - the catheters should be supplied with a protective sleeve to cover the cable connection between the generator and the catheter
- the distal section should have a hydrophilic coating to facilitate insertion and improve navigation through blood vessels - to be radiopaque along its entire length and feature a radiopaque marker positioned approximately 5 mm from the distal tip for precise fluoroscopic visualization - to incorporate an integrated hemostatic valve to minimize blood loss during the procedure - lengths: at least 45 cm, 65 cm, and 90 cm - sizes: at least 4F to 8F - with various tip configurations: Straight, Multipurpose, Hockey Stick, and Renal Double Curve - compatible with 0.018” and/or 0.035”/0.038” guide wires, depending on sheath size The set should include a guide sheath introducer, dilator, and adapter with a hemostatic valve. It should be non-pyrogenic, latex-free, and individually sterile packaged.
- catheter lengths: 80, 100, 140, and 150 cm - 2 tungsten radiopaque markers - compatible with 4, 5, and 6F introducer and 0.014”-0.035” wires - nominal pressure: 6–7 atm - RBP: 14–16 atm - dimensions: diameter 1.5–8 mm and length 20–200 mm
-- catheter length: 80, 140, and 200 cm - coated with a silicone layer - 2 radiopaque markers - tip profile: 0.036” - crossing profile: 0.057”–0.083”
-OTW technique - 0.018” compatible - minimum diameter range: 4.00–7.00 mm, in 1 mm increments - length: 40, 60, 80, 120, and 150 mm - compatible with 5F introducer - catheter length: 80 and 130 cm for all available balloon sizes
Documents (1)?
- Download📎 downloadtext/html · 31 KB
Details?
- Posted
- Nov 16, 2026
- Response deadline
- Dec 15, 2026, 10:59 PM UTC (29d)
- Type
- Tender
- Category
- 33111710
- Status
- open
- Estimated value
- EUR 390,244
- Buyer
- Public Health Institution Specialized Hospital for prevention, treatment and rehabilitation of cardiovascular diseases – Ohrid
- Jurisdiction
- MKD
- Reference #
- 796326-2026
- Has Description
- true
- Country
- MKD
- Tw Mul
- Ohrid
- Links Xml Mul
- https://ted.europa.eu/en/notice/796326-2026/xml
- Links Pdfs Eng
- https://ted.europa.eu/en/notice/796326-2026/pdfs
- Links Html Direct
- https://ted.europa.eu/en/notice/796326-2026/html
- Sub Lg
- MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD,
- Tv Cur
- EUR
- Deadline
- 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T12:00:00+01:00, 2026-12-09T
- Form
- competition
- Ojs
- 222/2026
- Eu
- no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu-funds, no-eu
- Legal
- 32014L0024
- Notice
- cn-social
- Total
- 390244
- Quantity
- 5, 9, 25, 5, 12, 12, 5, 5, 13, 25, 15, 5, 13, 25, 50, 3, 27, 15, 30, 20, 100, 5, 20, 10, 60, 10, 20, 10, 25, 2, 30, 25, 30, 10, 65, 15, 20, 10, 47, 10, 6, 1, 1, 5, 25, 25, 45, 5
- Dispatch
- Nov 13, 2026
- Dps
- none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, none, no
- Identifier
- LOT-0001, LOT-0002, LOT-0003, LOT-0004, LOT-0005, LOT-0006, LOT-0007, LOT-0008, LOT-0009, LOT-0010, LOT-0011, LOT-0012, LOT-0013, LOT-0014, LOT-0015, LOT-0016, LOT-0017, LOT-0018, LOT-0019, LOT-0020,
- Recurrence
- false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, false, fals
- Contract
- supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies, supplies,
- Document
- https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.gov.mk, https://e-nabavki.
- Publication
- 2026-11-16+01:00
- Accessibility
- n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-inc, n-in
- Official
- ENG
- Classification
- 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710, 33111710,
- Procedure
- The subject of the agreement consists of 48 separate parts
- Estimated
- 7967, 14560, 18699, 5609, 7414, 9365, 2276, 2243, 8032, 15040, 8536, 1617, 3008, 6052, 31024, 1682, 19021, 1707, 3956, 2764, 36260, 557, 6683, 1056, 5902, 6008, 1121, 1088, 3455, 1600, 975, 4471, 5365
- Variant
- not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-allowed, not-a
- Place
- MK003, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD, MKD
- Provided
- ted-esen, serv-prov
- Electronic
- true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, true, tr
- Organisation
- +38946277201
- Reserved
- no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no, no
- Public
- 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 2026-12-15+01:00, 20
- Award
- price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, price, pric
- Internal
- 02-817
- Selection
- epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-document, epo-procurement-do
- Procurement
- 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02-817/01, 02
- Main
- cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv, cpv,
- Exclusion
- epo-procurement-document
- Tender
- DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY, DAY,
- Guarantee
- The contracting party shall ask from the seller whose offer is chosen as the most favourable to provide a bank guarantee for quality and promptly fulfillment of the agreement in the amount of 10% of t
Contact
Similar open opportunities
See opportunities like this one
GovBidAlerts matches this solicitation to similar open bids across 114,000+ open bids from 2,500+ sources. Create a free account to unlock them.
Create free accountno credit card required
This listing is a summary from MKD's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.