closed🌐 Tarrant Regional Water District25-068
Rolling Hills Pump 6 Can Repair
Tarrant Regional Water District / Operations- Pipeline
All open bids & awards from Tarrant Regional Water District →
Description
During the visual inspection of the RH2 pump #6 pump can, multiple areas of damage were observed that occurred during a pump failure event. Smaller Vanes: - Damage to smaller vanes at the bottom of the pump can was noted. Larger Vanes: - Severe damage was observed on the larger vanes. Cavitation Damage: - Multiple areas of cavitation damage was identified throughout the pump can. Additional Repairs: - Due to the welding and cutting required to address the damage, there will be multiple areas in the bottom of the pump can that will need repair for any holidays (discontinuities or defects) in the coating. The coating repair process presents several challenges, primarily due to the need for climate control, the confined space, and limited access for multiple employees.
Details?
- Posted
- Jan 16, 2025
- Response deadline
- Feb 25, 2025, 8:00 PM UTC
- Status
- closed
- Buyer
- Tarrant Regional Water District
- Department
- Operations- Pipeline
- Jurisdiction
- Tarrant Regional Water District
- Reference #
- 25-068
- Has Description
- true
Contact
(817)335-2491
Finding similar opportunities…
This listing is a summary from Tarrant Regional Water District's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.