SolicitationActive6-B185-Q-00299-00
Parametric Amplifier and Accessories
ENERGY, DEPARTMENT OF / ENERGY, DEPARTMENT OF / ARGONNE NATL LAB - DOE CONTRACTORKey dates?
- Posted?
- Jun 2, 2026
- Response deadline?
- Jun 5, 2026, 9:00 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Solicitation
- Base type?
- Solicitation
- Set-aside?
- —
- Set-aside code?
- —
- PSC?
- 5996
NAICS?
Issuing office?
- Department?
- ENERGY, DEPARTMENT OF
- Sub-tier?
- ENERGY, DEPARTMENT OF
- Office?
- ARGONNE NATL LAB - DOE CONTRACTOR
- Office code?
- 089.8900.899031
- Organization type?
- OFFICE
- Office address?
- Lemont, IL, 60439, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Lemont
- State?
- Illinois
- Zip?
- 60439
- Country?
- UNITED STATES
Contacts?
- Laura Sanchezprimary
Description?
*THIS RFQ WILL BE EVALUATED BASED ON LOWEST PRICE, TECHNICALLY ACCEPTABLE METHODOLOGY* Looking to source a Parametric Amplifier and accessories with the following specifications: Raytheon BBN Fully Tested and Characterized JPA System Wide Bandwidth Josephson Junction Parametric Amplifier Tunable Center Frequency: 5.0 – 7.0 GHz Gain: 20 dB minimum Instantaneous Bandwidth: 300 MHz Noise temperature: 295 mK @ 6.8 GHz Matched input: 50 Ohm Compact Aluminum cryo-package Connector In/Out: 2.92mm K connectors - 1x Raytheon BBN JPA with S/N # - 1x JPA Bracket & MuMetal Shield - 1x Short cable 2.625" - 1x Cable 8.625" - 1x LNF Circulator LNF-CIC4_8A with 2nd mumetal shield - 1x Bias Tee - 1x LC Absorptive Filter Non-magnetic Cryogenic DC Block Broadband High out of Band Rejection Low Insertion Loss Compact Design Cryogenic Functionality (operates down to 10 mK) Pass Band: 0.2 to 18 GHz Block Band: DC to 500 kHz, 20 dB Insertion Loss: 0.5 dB Return Loss: 20 dB Connectors In/Out: SMA F/M Housing Material: Brass Finish: Abaloy Length: 1.03 inches connector to connector Please review all applicable documentation and provide a proposal response no later than 4:00 PM CST June 5, 2026. Within your proposal, please include: a fully executed copy of the ANL-70 Request for Quotation. a completed copy of the ANL-70A Reps & Certs the country of origin for the quoted equipment Any questions can be directed to the Contracting Officer. Thank you in advance for your participation.
Attachments (3)?
Similar open contracts
Metadata?
- Notice ID?
- f0c08a8ffe084fe4ad64e1c684ed5dcc
- Full path?
- ENERGY, DEPARTMENT OF.ENERGY, DEPARTMENT OF.ARGONNE NATL LAB - DOE CONTRACTOR
- Office code?
- 089.8900.899031
- Ingested?
- Jun 3, 2026
- Updated?
- Jun 20, 2026