GovBidAlerts
← All opportunities

NCI Radiation Oncology Branch Acquisition of Elekta Unity Linac System for Radiation Therapy

Key dates

Posted
Jul 20, 2026
Response deadline
Jul 30, 2026, 3:00 PM UTC
Archive date
Archive type
auto15

Classification

Notice type
Special Notice
Base type
Special Notice
Set-aside
Set-aside code
PSC
6515

NAICS

Issuing office

Department
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH OLAO
Office code
075.7529.75N980
Organization type
OFFICE
Office address
BETHESDA, MD, 20892, USA

Place of performance

Street
Street 2
City
Bethesda
State
Maryland
Zip
20892
Country
UNITED STATES

Contacts

Description

Notice of Intent to Sole Source Notice ID: NIH-NOI-26-PCA-NCI-09516 Agency / Office: Department of Health and Human Services (HHS), National Institutes of Health (NIH), National Cancer Institute (NCI) Notice Type: Special Notice Posted Date: July 20, 2026 Response Date: July 30, 2026, 11:00 AM Eastern Time NAICS Code: 339112 – Surgical and Medical Instrument Manufacturing PSC: 6515 – Medical and Surgical Instruments, Equipment, and Supplies Contracting Office Address: National Institutes of Health National Cancer Institute Description This is a combined synopsis / notice of intent to sole source and is not a request for competitive quotations or proposals. The National Institutes of Health (NIH), National Cancer Institute (NCI), on behalf of the Center for Cancer Research (CCR), Radiation Oncology Branch (ROB), intends to negotiate and award a sole-source firm-fixed-price contract to Elekta, Inc., 400 Perimeter Center Terrace NE, Suite 50, Atlanta, GA 30346, for the acquisition, delivery, installation, commissioning, training, and warranty of an integrated magnetic resonance-guided linear accelerator system. The statutory authority for this proposed sole-source action is 41 U.S.C. 3304(a)(1), as implemented by FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. Requirement The Government requires a fully integrated MR-guided linear accelerator system to support patient treatment and clinical research. The minimum salient characteristics include: 7 Megavoltage (MV) photon beam 160-leaf multileaf collimator (MLC) Onboard 1.5 Tesla (or greater) magnetic resonance imaging system Imaging protocols explicitly created for MR-guided external beam radiotherapy Capability for Diffusion Weighted Imaging (DWI) Capability for imaging and treating in the presence of patient motion MR receive coil with low attenuation of the radiation beam Dedicated MRI console for imaging guidance and control Patient positioning system including flat table, comfort mattress, and indexable table Quality assurance capabilities and supporting software Site planning, delivery, installation, commissioning, training, and warranty This equipment is mission-critical to patient treatment and clinical research because it enables high-resolution soft-tissue visualization and adaptive radiotherapy in a single integrated coordinate system, reducing geometric uncertainty associated with moving a patient between separate imaging and treatment systems. Sole Source Basis Based on market research, Elekta, Inc. is the only known responsible source capable of providing a commercially available, fully integrated 1.5 Tesla MR-guided linear accelerator system meeting the Government’s minimum needs. The Government reviewed other systems in the broader radiation oncology market, including lower-field MR-guided systems, CBCT-based adaptive radiotherapy systems, and standalone MRI platforms. These alternatives do not satisfy the Government’s minimum requirement for a fully integrated 1.5T MR-Linac with the required imaging, treatment, adaptive planning, and OEM installation capabilities. In addition, the proprietary nature of the system and the specialized site planning, shielding, installation, and commissioning requirements make Elekta the only responsible source for both the equipment and the associated implementation services. Response Information This notice is for informational purposes only. Any responsible source that believes it can meet the Government’s requirement may submit a capability statement for Government consideration. Capability statements must clearly demonstrate the vendor’s ability to provide a commercially available, fully integrated 1.5 Tesla (or greater) MR-guided linear accelerator system meeting all minimum salient characteristics, including OEM-authorized delivery, installation, commissioning, training, and warranty support. Responses must be submitted electronically no later than 11:00 AM Eastern Time on July 30, 2026. Responses shall be limited to 10 pages and must include: Company name and address UEI number Point of contact name, email address, and telephone number Technical description of the proposed system Evidence that the proposed system meets all minimum salient characteristics Evidence of OEM authorization for sale, installation, and support Relevant past performance information for similar Federal or commercial installations The Government will review all capability statements received by the closing date. A determination by the Government not to compete this proposed action based on responses to this notice is solely within the discretion of the Government. Primary Point of Contact Linda Smith linda.smith2@nih.gov Secondary Point of Contact Danielle Tines danielle.tines@nih.gov Disclaimer This notice does not constitute a solicitation, request for proposal, or request for quotation. The Government is not responsible for any costs incurred in responding to this notice.

Similar open contracts

Metadata

Notice ID
ec326829764c40f59e3eae061c26c0bc
Full path
HEALTH AND HUMAN SERVICES, DEPARTMENT OF.NATIONAL INSTITUTES OF HEALTH.NATIONAL INSTITUTES OF HEALTH OLAO
Office code
075.7529.75N980
Ingested
Jul 21, 2026
Updated
Jul 22, 2026