GovBidAlerts
← All opportunities

LE-MA900FP System Maintenance Service Agreement for Period 07/19/2026 through 07/18/2027

Key dates

Posted
Jun 11, 2026
Response deadline
Jun 22, 2026, 1:00 PM UTC
Archive date
Archive type
autocustom

Classification

Notice type
Presolicitation
Base type
Presolicitation
Set-aside
No Set aside used
Set-aside code
NONE
PSC
J066

NAICS

Issuing office

Department
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH OLAO
Office code
075.7529.75N980
Organization type
OFFICE
Office address
BETHESDA, MD, 20892, USA

Place of performance

Street
Street 2
City
State
Maryland
Zip
20892
Country
UNITED STATES

Contacts

Description

Requirements The Contractor shall provide all labor, material, and equipment necessary to maintain and provide preventive maintenance for one government-owned Sony LE MA900/0714076 for sorting cancer patients' cells used for ongoing clinical trial research. All maintenance services should be performed on-site in accordance with the manufacturer’s standard commercial maintenance practices. PREVENTIVE MAINTENANCE The Contractor shall perform 3 planned preventive maintenance during the contract period. Technically qualified factory-trained personnel shall perform Service. Service shall consist of thorough cleaning, calibration, adjusting, inspection, and testing of all equipment in accordance with the manufacturer’s latest established service procedures. All equipment shall be operationally tested through at least one (1) complete operating cycle at the end of the preventive maintenance inspection to ensure optimum and efficient performance. EMERGENCY SERVICE On-site, emergency repair service visit shall be provided during the term of this contract at no additional cost to the government. Emergency services shall be provided during normal working hours, Monday through Friday, excluding Federal Holidays. Upon receipt of notice that any part of the equipment is not functioning properly, the Contractor shall provide a one (1) hour initial response with a four (4) hour on-site response from a qualified factory-trained service representative to inspect the equipment and perform all repairs and adjustments necessary to restore the equipment to normal and efficient operating condition. Emergency service calls shall not replace the necessity for planned preventative maintenance. All labor and travel will be included. 3.3 REPLACEMENT PARTS The Contractor shall furnish all required replacement parts at no additional cost to the Government, with the exception of consumables. Parts shall be new to the original equipment specifications. Parts will be delivered the next day. 3.4 SOFTWARE UPDATES/SERVICE The Contractor shall provide Software Service and updates in accordance with the manufacturer’s latest established service procedures, to include telephone access to technical support for use of program software and troubleshooting of the operating systems, at no additional cost to the Government. The contractor shall receive advance approval for the installation of all software updates and revisions from the Government. Defective software shall be replaced at no additional cost to the government. The Contractor shall provide unlimited clinical technical telephone support (24hrs/day, 7 days/week) for troubleshooting for the instrument and clinical application support (M-F 8 am-9 pm), excluding Federal holidays. Remote service support for software and instrument calibration shall be provided by Sony Biosciences at no additional cost. 3.5 SERVICE EXCLUSIONS The Contractor shall not be responsible for any repairs necessitated by abuse, neglect, vandalism, Acts of God, fire, or water. These repairs shall be the subject of a separate purchase order and shall not be performed under this contract. 3.6 PERIOD OF PERFORMANCE The base period of performance shall be for twelve (12) months from 07/19/26 through 07/18/27 with 12-month option periods. 3.7 PERSONNEL QUALIFICATIONS Technically qualified factory-trained personnel shall have a minimum of three (3) years of factory training and experience in the service of Sony LE MA900/0714076 located at NIH/NCI 9000 Rockville pike Building 10, CRC rm 3W-5889, Bethesda, MD 20892, as covered by this contract. All primary service personnel shall have at least one backup support person with at least the same level of expertise on the equipment covered by this contract.

Attachments (1)

Similar open contracts

Metadata

Notice ID
e68dd147071a450081e58ee80d0caf58
Full path
HEALTH AND HUMAN SERVICES, DEPARTMENT OF.NATIONAL INSTITUTES OF HEALTH.NATIONAL INSTITUTES OF HEALTH OLAO
Office code
075.7529.75N980
Ingested
Jun 12, 2026
Updated
Jun 23, 2026