The U.S. Food and Drug Administration requires one (1) complete, turnkey single-axis (one degree-of-freedom) linear motion calibration system, commonly described as a shake table, with control software, for laboratory calibration, verification, and validation testing of inertial measurement devices. The system shall be fully assembled, factory-tested, and factory-calibrated prior to shipment, requiring only unpacking, cable connection, and software installation by the end user. The Government seeks sources able to provide a system meeting, at minimum, the following salient performance characteristics. These are stated in approximate terms for market research; the full minimum specification will accompany any resulting solicitation. • Programmable single-axis linear motion under closed-loop position control with real-time feedback, capable of arbitrary user-defined waveforms including multi-frequency superposition of at least three simultaneous components. Pre-programmed, fixed-routine-only calibrators are not sought. • A motion envelope on the order of 0.1 to 10 Hz in frequency, sub-millimeter to approximately twenty millimeters in displacement, and up to approximately one g in acceleration, with demonstrated small-amplitude positioning accuracy at the sub-millimeter level. • An integrated position sensor and an integrated reference accelerometer, each factory calibrated with NIST-traceable certificates. • Safety features including a hard-wired emergency stop, motion limits, over-current protection, and fault detection with automatic safe shutdown. • Benchtop form factor suitable for standard laboratory power (110 to 120V, or universal input) without special power conditioning or floor reinforcement. • Control software operable in a standalone configuration with no required internet, cloud, or subscription, a programmable interface compatible with MATLAB, Python, or an equivalent industry-standard environment, and non-proprietary data import and export. • Software and electronic content conforming to Section 508 accessibility standards, supported by a Voluntary Product Accessibility Template or equivalent. Estimated quantity: one (1) each. Anticipated delivery: within approximately 90 days after award. Place of delivery: FDA White Oak campus, Silver Spring, Maryland. Applicable standards: NIST-traceable calibration; Section 508. Installation, user training, technical documentation, and a commercial warranty are included in the anticipated requirement.

Other notices in this solicitation

Similar open contracts

Metadata

Notice ID
c132e199aa064983925081b8ac5b2a97
Full path
HEALTH AND HUMAN SERVICES, DEPARTMENT OF.FOOD AND DRUG ADMINISTRATION.FDA OFFICE OF ACQ GRANT SVCS
Office code
Ingested
Jul 22, 2026
Updated
Jul 22, 2026