CASCADE SCBA SYSTEM
DEPT OF DEFENSE / DEPT OF THE ARMY / W6QM MICC-FT DRUMKey dates?
- Posted?
- Aug 12, 2025
- Response deadline?
- Aug 13, 2025, 11:00 PM UTC
- Archive date?
- —
- Archive type?
- autocustom
Classification?
- Notice type?
- Combined Synopsis/Solicitation
- Base type?
- Combined Synopsis/Solicitation
- Set-aside?
- Total Small Business Set-Aside (FAR 19.5)
- Set-aside code?
- SBA
- PSC?
- 4240
NAICS?
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE ARMY
- Office?
- W6QM MICC-FT DRUM
- Office code?
- —
- Organization type?
- OFFICE
- Office address?
- FORT DRUM, NY, 13602-5220, USA
Place of performance?
- Street?
- Deliver to address: James FerraroBLDG: 772: 6446-Indiana Ave.Fort Leonard Wood, MO. 65473
- Street 2?
- —
- City?
- —
- State?
- —
- Zip?
- 65473
- Country?
- —
Contacts?
- James Ferraroprimary
Description?
UNICUS IV:MUST HAVE A NEMA 4 RATED ELECTRICAL ENCLOSURE w/ UL LISTED CONTROL PANELMUST COME WITH PARTS AND REPAIR MANUALSMUST HAVE AIR INLET FILTER MAINTENANCE INDICATORMUST HAVE A VIRUS FREE INTAKE FILTERATION SYSTEMMUST HAVE (4) ASME CODE STAMPED AIR CYLINDERS INSTALLED IN AN INTEGRAL RACKMUST HAVE A P5 B-SECURUS PURIFICATION SYSTEMMUST BE AT LEAST A 5 STAGE COMPRESSOR MUST HAVE AT LEAST A 20 HP ELECTRIC MOTORMUST HAVE A PLC BASED CONTROLLER WITH AT LEAST A 6.75? SCREENMUST HAVE EMERGENCY STOP PUSH BUTTONMUST HAVE A NFPA 1901 2016 EDITION COMPLIANT 3 POSITION CONTAINMENT FILL STATION TO FIT SCBA OR SCUBA CYLINDERS UP TO 31?MUST HAVE CO/H2S MONITORING SYSTEM WITH AUDIBLE ALARMMUST BE ABLE TO FILL (3) SCBA OR SCUBA CYLINDERS SIMULTAINEOUSLY MUST BE 208V 3PHMUST BE CAPABLE OF PRODUCING 6000 PSIMUST HAVE A CHARGING RATE OF AT LEAST 25 SCFMMUST HAVE A SYSTEM OF AUDIBLE ALARMS WITH SAFETY SHUTDOWNSMUST HAVE COMPRESSOR LOW OIL PRESSURE AND HIGH TEMPERATURE SHUTDOWNSMUST HAVE AUTOMATIC CONDENSATE DRAIN SYSTEM WITH NON-CORROSIVE CONDENSATE RESERVOIR w/ INDICATOR TO SHUTDOWN WHEN FULLMUST HAVE SOUND ATTENUATING ENCLOSURE WITH TURN LATCH AND LIFT OFF TYPE HINGES
Other notices in this solicitation?
- Combined Synopsis/SolicitationCASCADE SCBA SYSTEMAug 12, 2025LATEST
Similar open contracts
Metadata?
- Notice ID?
- baab143a03d14c989529cb8a35359b58
- Full path?
- DEPT OF DEFENSE.DEPT OF THE ARMY.W6QM MICC-FT DRUM
- Office code?
- —
- Ingested?
- May 2, 2026
- Updated?
- Jul 11, 2026