Sources SoughtActiveSLAC_RFP_367094
RPC Power Factor Correction Work Package 1 - Demolition
ENERGY, DEPARTMENT OF / ENERGY, DEPARTMENT OF / SLAC Natl Accel Lab -DOE ContractorKey dates?
- Posted?
- Jul 18, 2026
- Response deadline?
- Jul 24, 2026, 5:00 PM UTC
- Archive date?
- —
- Archive type?
- autocustom
Classification?
- Notice type?
- Sources Sought
- Base type?
- Sources Sought
- Set-aside?
- No Set aside used
- Set-aside code?
- NONE
- PSC?
- —
Issuing office?
- Department?
- ENERGY, DEPARTMENT OF
- Sub-tier?
- ENERGY, DEPARTMENT OF
- Office?
- SLAC Natl Accel Lab -DOE Contractor
- Office code?
- 089.8900.899040
- Organization type?
- OFFICE
- Office address?
- Menlo Park, CA, 94025, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- Menlo Park
- State?
- California
- Zip?
- 94025
- Country?
- UNITED STATES
Contacts?
- doreen agbayaniprimary
Description?
Introduction and Overview: The subcontractor must provide all labor, oversight, tools, materials, equipment, and services necessary to complete the work safely and in compliance with approved BIO documents as well as SLAC, DOE, and ES&H standards. SLAC receives power at its Master Substation (MSS) from a PG&E 230kV transmission line via two 230kV/12.47kV stepdown transformers. SLAC identifies that its AC power system encounters power factor issues at the point of connection (POC) with PG&E, where the power factor strays outside the contractual range (0.97 lag to 0.99 lead). This deviation stems from various factors, including reactive power imbalances, capacitive or inductive loads, etc. Consequently, suboptimal power factor conditions can result in increased power losses, reduced system efficiency, and involve potential penalties imposed by PG&E. To address this challenge, SLAC plans to implement power factor correction measures through the installation of two switched power factor correction (PFC) systems – one on 12.47 kV Bus-1 and another on 12.47kV Bus-2 at the Master Substation (MSS). These PFC units will dynamically improve reactive power flow, compensating for system reactive power demand, and maintaining the overall power factor within the required range. Enhancing power factor correction in this manner will optimize energy utilization, reduce system losses, and ensure continued compliance with PG&E contractual requirements. Purpose: Prior to the installation of the new power factor correction equipment, it is necessary to demolish existing buildings (B308 and B311) with equipment inside them to create adequate space within the MSS Yard. This Statement of Work outlines the scope for the demolition, disassembly, and removal of existing assets, including metal buildings B308 and B311, a non-operational synchronous condenser, and the associated electrical equipment and cabling and wiring serving the condenser. All identified buildings and equipment are located in the SLAC MSS Yard. THIS IS FOR SOURCES SOUGHT ONLY, DO NOT SUMBIT BIDS. While the draft RFP package has been included with this post, the RFP has not been released. Interested vendors should express their interest by sending their capabilities statement to Doreen Agbayani at doreena@slac.stanford.edu.
Attachments (25)?
- Download📎 B2_00_RFP_Cover_DRAFT.pdfapplication/pdf · 622 KB
- Download📎 B2_05.1_Fixed_Price_Construction_March2024_DRAFT.pdfapplication/pdf · 1.3 MB
- Download📎 B2_03.0_Section_C_%28Specifications_SOW%29_DRAFT.pdfapplication/pdf · 586 KB
- Download📎 B2_04_Section_F_%28Deliveries_Performance%29_DRAFT.pdfapplication/pdf · 641 KB
- Download📎 B2_05.0_Section_G_%28General_TsCs%29_DRAFT.pdfapplication/pdf · 235 KB
- Download📎 B2_07.1_DBA_WD_CA20260018_7.14.26_Mod_06_DRAFT.pdfapplication/pdf · 3.7 MB
- Download📎 B2_09.0_Section_L_Instruction_to_Offerors_DRAFT.pdfapplication/pdf · 322 KB
- Download📎 B2_07.7_Final_Inspection_Report_DRAFT.pdfapplication/pdf · 123 KB
- Download📎 B2_06_Section_H_%28Special+TsCs%29_DRAFT.pdfapplication/pdf · 185 KB
- Download📎 B2_07.6_NTP_Submittal_Checklist_061424_DRAFT.pdfapplication/pdf · 582 KB
- Download📎 B2_02_Section_B_%28Supplies_or_Services_and_Price_Costs%29_DRAFT.pdfapplication/pdf · 631 KB
- Download📎 B2_09.1_Section_L_Attachment_A_Proposal_Breakdown_Sheet_DRAFT.pdfapplication/pdf · 122 KB
- Download📎 B2_07.3_Work_Classification_Form_367094_DRAFT.pdfapplication/pdf · 649 KB
- Download📎 B2_07.0_Section_J_%28List_of_Attachments%29_DRAFT.pdfapplication/pdf · 170 KB
- Download📎 B2_03.3_SLAC+BIO+Adopted+Codes+and+Standards+%28Updated+01012025%29_DRAFT.pdfapplication/pdf · 466 KB
- Download📎 B2_07.2_Subcontractor_Form_IIPP_052121_DRAFT.pdfapplication/pdf · 228 KB
- Download📎 B2_08.0_Section_K_%28Rep_and_Certs%29_DRAFT.pdfapplication/pdf · 163 KB
- Download📎 B2_01_Section_A_%28Subcontract_Form%29_DRAFT.pdfapplication/pdf · 634 KB
- Download📎 B2_07.4_SF1413_DRAFT.pdfapplication/pdf · 699 KB
- Download📎 B2_03.1_SOW_RPC+WP1+Demolition_R3_DRAFT.pdfapplication/pdf · 386 KB
- Download📎 B2_08.1_Reps_and_Certs_Supplement_DRAFT.pdfapplication/pdf · 65 KB
- Download📎 B2_07.5_SubcontractorFormSQF_DRAFT.pdfapplication/pdf · 322 KB
- Download📎 B2_10_Section_M_Evaluation_Methodology_DRAFT.pdfapplication/pdf · 241 KB
- Download📎 B2_07.8_Construction_Subcontracts_Final_Release_DRAFT.pdfapplication/pdf · 186 KB
- Download📎 B2_09.2_Section_L_Attachment_B_SLAC_Question%26Answer_Log_%28RFI%29_DRAFT.pdfapplication/pdf · 754 KB
Similar open contracts
Metadata?
- Notice ID?
- 99bbf7310e21477c91b960e33506e947
- Full path?
- ENERGY, DEPARTMENT OF.ENERGY, DEPARTMENT OF.SLAC Natl Accel Lab -DOE Contractor
- Office code?
- 089.8900.899040
- Ingested?
- Jul 18, 2026
- Updated?