GovBidAlerts
← All opportunities

6515--Sources Sought Ceiling lift for Milwaukee VA.

Key dates

Posted
Jul 13, 2026
Response deadline
Jul 22, 2026, 4:59 AM UTC
Archive date
Archive type
autocustom

Classification

Notice type
Sources Sought
Base type
Sources Sought
Set-aside
Set-aside code
PSC
6515

NAICS

Issuing office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
252-NETWORK CONTRACT OFFICE 12 (36C252)
Office code
036.3600.36C252
Organization type
OFFICE
Office address
MILWAUKEE, WI, 53214, USA

Place of performance

Street
Milwaukee VA 53295
Street 2
City
State
Zip
Country

Contacts

Description

Page 2 of 3 THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE. The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide Ceiling Lift for the Milwaukee VAMC. General Requirements: Salient Characteristics: i. The Lift Unit shall be constructed of a steel frame system driven by a gear-reduced, high-torque, horizontal axis motor. 1. The ceiling lift motor shall have an integrated Class III scale that allows users to read weights off the hand control. 2. 2 lifts with minimum 770 lbs weight capacity a. Weight capacity shall be achieved using a single lift motor 3. Electronic soft-start and soft-stop motor control. 4. Shall have an emergency manual lowering device. This emergency manual lowering device cord shall be red. Operation of the emergency manual lowering device shall be in such a way that users can apply continuous pull to the cord to facilitate slow descent of the patient. 5. Emergency stopping device. 6. Current limiter for circuit protection in case of overload. 7. Safety device that stops the motor to lift when batteries are low. 8. Emergency brake (in case of mechanical failure). 9. Hanger bar shall be able to reach the floor. 10. Cab: VO plastic fire retardant, UL 94. 11. Hand controller shall be able to be stored securely to the hanger bar. 12. The safe working load of the ceiling lift motor shall be clearly labeled on the outside of the ceiling lift motor. 13. The life cycle (number of charging cycles) for batteries shall comply with IEC 6100-1-2. 14. Provide rechargeable batteries with up to 120 transfers with a load of 200lbs (74kg) (for repositioning) 15. The ceiling lift system (motor/hanger assembly) shall be approved for use with Guldmann Repositioning, High Back, Twin Turner and Limb Lifter loop slings. ii. Two (2) Basic High Slings: 1. The straps shall meet ISO 10535, Appendix A guidelines. The straps shall ensure the patient s safety by preventing the patient from falling out of the sling. 2. The sling shall meet ISO 10535, Appendix A guidelines. The sling shall cradle the body of the patient. Bariatric slings shall be rated to a minimum of 770 lbs. iii. Two (2) Hanger Bars: The hanger bar style shall be the four (4) suspension point style compatible with the lift strap. iv. Continuous charge track systems 1. Two (2) Double Rail continuous charge track systems with bathroom access 2. The Ceiling Track shall be made from high strength extruded aluminum. Provide anchor supports at ceiling substrate 3. Installed rail shall be security tested for 1.5 times greater than the motor s weight capacity and maximum allowable deflection of a horizontal rail is no more than 1/16th inch per 7.87 inch of track length per ISO 10535 standards. All interested firms who can meet the requirements stated above should respond, in writing, INCLUDING ALL THE FOLLOWING: Company name. Address. Point of contact (name/title/telephone number/e-mail address). FSS / SEWP Contract number, if applicable. SAM Unique ID number. Tax ID number. Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies. A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above. Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer. Location of Manufacturer Submit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), July 21st 2026. 36C25226Q0596 Ceiling lift-3215 shall be referenced on all correspondence regarding this announcement. TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED. The NAICS Code 339112, Surgical and Medical Instrument Manufacturing, is applicable to this acquisition; the size standard is 1,000 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.

Attachments (1)

Similar open contracts

Metadata

Notice ID
96c61c47427b4266bf84347f4f45c8aa
Full path
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.252-NETWORK CONTRACT OFFICE 12 (36C252)
Office code
036.3600.36C252
Ingested
Jul 14, 2026
Updated
Jul 14, 2026