GovBidAlerts
← All opportunities

Electrosurgical unit (ESU)

Key dates

Posted
Sep 10, 2026
Response deadline
Sep 16, 2026, 5:00 PM UTC
Archive date
Sep 17, 2026
Archive type
autocustom

Classification

Notice type
Combined Synopsis/Solicitation
Base type
Combined Synopsis/Solicitation
Set-aside
No Set aside used
Set-aside code
NONE
PSC
6515

NAICS

Issuing office

Department
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
FOOD AND DRUG ADMINISTRATION
Office
FDA OFFICE OF ACQ GRANT SVCS
Office code
075.7524.75F401
Organization type
OFFICE
Office address
Rockville, MD, 20852, USA

Place of performance

Street
—
Street 2
—
City
Silver Spring
State
Maryland
Zip
20993
Country
UNITED STATES

Contacts

Description

All equipment shall be newly manufactured. It shall not be used, refurbished, reconditioned, remanufactured, or previously used for demonstration. The equipment and all included accessories shall be new, unused, and in full working condition at the time of delivery. Salient characteristics and any single-source need The salient physical, functional, and performance characteristics the equipment must meet are stated under Minimum technical requirements below: Minimum technical requirements The equipment shall meet the following minimum requirements. Display and user interface A touchscreen display for user interaction and parameter control Tissue impedance monitoring Monitoring of tissue impedance at a minimum rate of 434,000 times per second, providing real-time feedback and energy delivery adjustment Output frequency Output frequency within the range of 400 kHz to 500 kHz Operating modes The equipment shall support the following operating modes. Monopolar CUT (Pure) Monopolar CUT (Blend) Monopolar COAG (Fulgurate) Monopolar COAG (Spray) Monopolar COAG (Soft) Bipolar coagulation Vessel sealing Electrical and safety Compliance with all applicable Federal, state, and local safety standards Required accessories The contractor shall provide all accessories necessary to fully operate the equipment in every operating mode listed above. At minimum the following shall be included. Monopolar electrode and holster with switch, compatible with all monopolar modes. Patient return electrode for monopolar operation. Bipolar forceps, cord, and footswitch for bipolar coagulation. Vessel sealer with switch for vessel sealing mode. All accessories shall be compatible with the delivered equipment and ready for use upon delivery.

Attachments (2)

Other notices in this solicitation

Similar open contracts

Metadata

Notice ID
93cb831e158f4ae090cfb682c880d645
Full path
HEALTH AND HUMAN SERVICES, DEPARTMENT OF.FOOD AND DRUG ADMINISTRATION.FDA OFFICE OF ACQ GRANT SVCS
Office code
075.7524.75F401
Ingested
Sep 11, 2026
Updated
Sep 13, 2026