Sources SoughtActive36C25026Q0755
4410--610 - COMPRESSORS Boiler Plant Bldg 76 - ENGINEERING, NIHCS
VETERANS AFFAIRS, DEPARTMENT OF / VETERANS AFFAIRS, DEPARTMENT OF / 250-NETWORK CONTRACT OFFICE 10 (36C250)Key dates?
- Posted?
- Jul 17, 2026
- Response deadline?
- Jul 22, 2026, 3:00 PM UTC
- Archive date?
- —
- Archive type?
- autocustom
Classification?
- Notice type?
- Sources Sought
- Base type?
- Sources Sought
- Set-aside?
- —
- Set-aside code?
- —
- PSC?
- 4410
NAICS?
Issuing office?
- Department?
- VETERANS AFFAIRS, DEPARTMENT OF
- Sub-tier?
- VETERANS AFFAIRS, DEPARTMENT OF
- Office?
- 250-NETWORK CONTRACT OFFICE 10 (36C250)
- Office code?
- 036.3600.36C250
- Organization type?
- OFFICE
- Office address?
- DAYTON, OH, 45428, USA
Place of performance?
- Street?
- Department of Veterans Affairs Northern Indiana Healthcare System 1700 East 38th Street
- Street 2?
- 1700 East 38th Street
- City?
- Marion
- State?
- Indiana
- Zip?
- 46953
- Country?
- UNITED STATES
Contacts?
- Tim GarrityprimaryContracting Specialist
Description?
STATEMENT OF WORK Introduction: The Department of Veterans Affairs VA Northern Indiana Health Care System (VANIHCS) located at 1700 East 38th Street, Marion, Indiana, 46953 requires two (2) compressors for the Boiler Plant. Background: Project Overview: Purchase two (2) compressors and have them installed at the Boiler Plant in Building 76. Period of Performance: Start Date: The project will commence by October 1, 2026. End Date: The project is expected to be completed by October 31, 2026. Place of Performance: Marion VA Medical Center,1700 East 38TH Street, Marion IN. 46953-4589 Scope: Project Deliverables: The project will produce the following key deliverables: Deliverable 1: Contractor will provide two (2) R4-11I- FIXED SPEED 4-11KW Compressors Deliverable 2: : Contractor will provide two (2) R4 Premium Efficiency Rotary Screw Compressor- 145 PSIg- Total Air System Deliverable 3: Contractor will provide two (2) Drive motor 208-230/460V 60Hz with Star Delta Starter Deliverable 4: Contractor will provide two (2) Coolant: Factory Filled with Ultra Coolant Deliverable 5: Contractor will provide two (2) 80 Gallon Tank Mounted Deliverable 6: Contractor will provide two (2) Controller: XE-70M Microprocessor Controller Deliverable 7: Contractor will provide two (2) Low sound enclosure Deliverable 8: Contractor will provide two (2) PORO Deliverable 9: Contractor will provide two (2) Start up kits Services: The following services will be provided as part of this project: Service 1: Contractor will then install and start up both RA-11I-FIXED SPEED 4-11KW Compressors at the Marion Boiler Plant in Building 76.
Attachments (1)?
- Download📎 36C25026Q0755_1.docxapplication/octet-stream · 29 KB
Similar open contracts
Metadata?
- Notice ID?
- 7bf78a5787ab4f0d81c4a2cd8212bfcf
- Full path?
- VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.250-NETWORK CONTRACT OFFICE 10 (36C250)
- Office code?
- 036.3600.36C250
- Ingested?
- Jul 18, 2026
- Updated?
- Jul 20, 2026