Special NoticeActivePANHCA-26-029301
Enhanced Vyleater Vial Disposal System Model II-Xe
DEPT OF DEFENSE / DEPT OF THE ARMY / W40M MRC0 WESTKey dates?
- Posted?
- Jun 2, 2026
- Response deadline?
- Jun 9, 2026, 5:30 PM UTC
- Archive date?
- —
- Archive type?
- auto15
Classification?
- Notice type?
- Special Notice
- Base type?
- Special Notice
- Set-aside?
- No Set aside used
- Set-aside code?
- NONE
- PSC?
- 6530
NAICS?
Issuing office?
- Department?
- DEPT OF DEFENSE
- Sub-tier?
- DEPT OF THE ARMY
- Office?
- W40M MRC0 WEST
- Office code?
- 021.2100.MEDCOM.USAHCA.W81K00
- Organization type?
- OFFICE
- Office address?
- JBSA FT SAM HOUSTON, TX, 78234-4504, USA
Place of performance?
- Street?
- —
- Street 2?
- —
- City?
- JBSA Ft Sam Houston
- State?
- Texas
- Zip?
- 78234
- Country?
- UNITED STATES
Contacts?
- Derrick J Johnsonprimary
Description?
Enhanced Vyleater Vial Disposal System Model II-Xe. DPALS process about 3,000 cytology thin prep vials per month that need to be disposed of in a safe and efficient manner. The device must be able to accommodate vials in their whole form. The device must be explosion resistant to substances with a flash point of 27 °C / 81 °F. The devise should separate solid waste materials in a separate container from the liquid waste. The device should be self-contained. The disposal system must comply with hazard waste guidelines. The device should not alter the waste material. The device should come with training for all technicians that will be required to utilize it. The device should be able to withstand mild exposure to environmental elements. The device needs to accommodate approximately 300 vials being disposed of per day, with each vial holding approximately 20ml of methanol-based solution. The regional technical support and service from manufacturer should be available in case the parts need to be ordered to repair. The operators training support should be available as requested. The device should be simple and easy to use for non-experienced operators. The device should be durable and easy to clean.
Attachments (1)?
- Download📎 Notice+of+Intent+to+Sole+Source+PANHCA-26-P-029301.pdfapplication/pdf · 131 KB
Other notices in this solicitation?
- Sources SoughtEnhanced Vyleater Vial Disposal System Model II-XeMay 15, 2026LATEST
Similar open contracts
Metadata?
- Notice ID?
- 66cbb83323bb4982a8528834925f1d26
- Full path?
- DEPT OF DEFENSE.DEPT OF THE ARMY.W40M MRC0 WEST
- Office code?
- 021.2100.MEDCOM.USAHCA.W81K00
- Ingested?
- Jun 3, 2026
- Updated?
- Jun 25, 2026