GovBidAlerts
← All opportunities
This notice has been superseded. See the latest notice: 6515--Body Composition Analysis Scale (Award Notice)

6515--InBody Composition Analysis Scale *BRAND NAME OR EQUAL*

Key dates

Posted
Jun 3, 2026
Response deadline
Jun 25, 2026, 4:00 AM UTC
Archive date
Archive type
autocustom

Classification

Notice type
Sources Sought
Base type
Sources Sought
Set-aside
Set-aside code
PSC
6515

NAICS

Issuing office

Department
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
257-NETWORK CONTRACT OFFICE 17 (36C257)
Office code
036.3600.36C257
Organization type
OFFICE
Office address
San Antonio, TX, 78240, USA

Place of performance

Street
Department of Veterans Affairs VA Harlingen Medical HealthCare Center 2601 Veterans Way Attn: Warehouse
Street 2
2601 Veterans Way Attn: Warehouse
City
Harlingen
State
Texas
Zip
78550
Country
UNITED STATES

Contacts

Description

Sources Sought Notice Sources Sought Notice Page 5 of 5 SOURCES SOUGHT NOTICE *= Required Field Sources Sought Notice Page 1 of 5 THIS NOTICE IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES - it does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP) or a promise to issue an RFQ, IFB or RFP in the future. This notice does not commit the VA to contract for any supply or service. Further, the VA is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this source sought notice. The VA will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry. It is the responsibility of potential offerors to monitor the Governmentwide Point of Entry for additional information pertaining to this requirement. The anticipated NAICS code is: 339112. SOURCES SOUGHT NOTICE InBody 380 Body Composition Analyzer 1. PURPOSE This Sources Sought Notice is issued solely for market research and information-gathering purposes. It does not constitute a solicitation, commitment, or authorization to procure any supplies or services. The Government is seeking to identify qualified and capable vendors that can provide the InBody 380 Body Composition Analyzer or an equal product that meets all salient characteristics listed below. 2. BACKGROUND The Government has a requirement for a professional-grade body composition analyzer for use in clinical, wellness, or research environments. The device must provide accurate, quick, and noninvasive assessment of body composition metrics used in patient evaluation and treatment planning. 3. REQUIRED ITEM Brand Name: InBody 380 Body Composition Analyzer OR EQUAL: Vendors may offer an equivalent product, provided the item meets or exceeds all salient characteristics included in Section 4. 4. SALIENT CHARACTERISTICS (Minimum Requirements) Any offered product must meet all of the following: Measurement Technology Utilizes Direct Segmental Multi Frequency Bioelectrical Impedance Analysis (DSM BIA) Employs multiple frequencies for increased accuracy Provides non invasive, rapid testing without the use of empirical estimation formulas Measurement Parameters (minimum required) Weight Skeletal Muscle Mass Body Fat Mass Percent Body Fat Body Mass Index (BMI) Basal Metabolic Rate (BMR) Total Body Water, Intracellular Water, and Extracellular Water Segmental Lean Analysis (right arm, left arm, trunk, right leg, left leg) Segmental Fat Analysis Visceral Fat or comparable abdominal fat assessment Impedance values at multiple frequencies for each segment Operational Requirements Test duration: 90 seconds or less User-friendly interface with onboard screen Ability to output full results sheet to printer or computer Ability to store or export data through USB, Bluetooth, or software interface Weight capacity: Minimum 330 lb. (150 kg) Accuracy suitable for clinical or research use Powered by standard AC adapter Physical & Durability Requirements Stable platform with integrated hand electrodes Compact, portable, and appropriate for clinical environments Minimum 1 year manufacturer warranty Standards & Compliance FDA registered or compliant medical device Must comply with all applicable electrical and safety standards 5. REQUESTED INFORMATION FROM INTERESTED VENDORS Vendors responding to this notice should submit the following: Company information (name, address, UEI, POC). Socioeconomic status (SB, WOSB, SDVOSB, 8(a), HUBZone, etc.). Capability statement addressing ability to meet requirements. Technical documentation showing how proposed equipment meets each salient characteristic. Product literature for the proposed brand name or equal device. Estimated delivery timeframe. Applicable contract vehicles (GSA, SEWP, VA FSS, etc.). Warranty information. 6. SUBMISSION DETAILS All responses must be submitted electronically via email to: Contract Specialist: Matthew.Lee5@va.gov Contract Officer: Tommy.Haire@va.gov Subject line: Sources Sought InBody 380 Body Composition Analyzer Responses requested no later than: June 24, 2026 7. DISCLAIMER This notice is not a solicitation. The Government will not pay for any information received in response to this notice and will not reimburse any costs associated with preparing or submitting responses. The results of this Sources Sought may influence the acquisition strategy for any future solicitation. End of Document

Attachments (2)

Other notices in this solicitation

Similar open contracts

Metadata

Notice ID
5e361962f0e44d87b2a5bd91f9ac675d
Full path
VETERANS AFFAIRS, DEPARTMENT OF.VETERANS AFFAIRS, DEPARTMENT OF.257-NETWORK CONTRACT OFFICE 17 (36C257)
Office code
036.3600.36C257
Ingested
Jun 5, 2026
Updated
Jul 11, 2026