IFBclosed🌐 Virginia (eVA)638-14
HVAC UPGRADES AT THE EQUIPMENT BUREAU FACILITY
Other eVA Localities
Description
HEATING, VENTILATION AND AIR-CONDITIONING (HVAC) UPGRADES AT THE EQUIPMENT BUREAU FACILITY LOCATED AT 2701 SOUTH TAYLOR STREET IN ARLINTON, VIRIGINIA. THE PROJECT WILL INCLUDE, BUT NOT BE LIMITED TO UPGRADING AND COMPONENT REPLACEMENT OF THE HVAC SYSTEMS AND RELATED CONTROLS SERVING BOTH THE OFFICE/ADMINISTRATIVE/PARTS STORAGE AREAS AND THE VEHICLE REPAIR BAYS. THE WORK SHALL ALSO INCLUDE REVISIONS TO THE ELECTRICAL DISTRIBUTION SYSTEM SERVING THE HVAC SYSTEM. STRUCTURAL REINFORCING ON THE ROOF IS REQUIRED TO SUPPORT NEW HVAC EQUIPMENT. TWO OF THE VEHICLE REPAIR BAYS SHALL BE MODIFIED TO PROVIDE CAPABILITY TO MAINTAIN CNG-FUELED VEHICLES, WHICH SHALL REQUIRE CONSTRUCTION OF A FIRE-RATED ENCLOSURE. ADDITIONALLY THE WORK SHALL INCLUDE A WELDING EXHAUST SYSTEM AND MONITORING OF BUILDING POWER CONSUMPTION AND GENERATOR OPERATION THROUGH THE BUILDING AUTOMATED SYSTEM (BAS).
Details?
- Posted
- Feb 18, 2014
- Response deadline
- Feb 20, 2014, 2:30 PM UTC
- Type
- IFB
- Category
- Construction
- Status
- closed
- Buyer
- Other eVA Localities
- Jurisdiction
- Virginia (eVA)
- Location
- ARLINGTON, VIRGINIA
- Reference #
- 638-14
- App
- VBO
- Agency
- S000
- Doctype
- SO
- Version
- 4
- Commcode
- 91450, 91000, 94155
- Commdesc
- Heating, Ventilating and Air Conditioning (HVAC),BUILDING MAINTENANCE, INSTALLATION AND REPAIR SERVICES,HVAC Systems Maintenance and Repair, Power Plant
- Longdesc
- HEATING, VENTILATION AND AIR-CONDITIONING (HVAC) UPGRADES AT THE EQUIPMENT BUREAU FACILITY LOCATED AT 2701 SOUTH TAYLOR STREET IN ARLINTON, VIRIGINIA. THE PROJECT WILL INCLUDE, BUT NOT BE LIMITED TO
- Doccddesc
- Invitation for Bids (IFB)
- Commlinedesc
- []
- Lastupdatedate
- Oct 13, 2018
Contact
Angela Gaskins
Finding similar opportunities…
This listing is a summary from Virginia (eVA)'s open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.
Raw record
{
"id": "VBO:IFB:S000:92807",
"app": "VBO",
"doccd": "IFB",
"agency": "S000",
"status": "Closed",
"doctype": "SO",
"pubdate": "2014-02-18T12:13:00Z",
"version": "4",
"workloc": "ARLINGTON, VIRGINIA",
"category": "Construction",
"commcode": [
"91450, 91000, 94155"
],
"commdesc": [
"Heating, Ventilating and Air Conditioning (HVAC),BUILDING MAINTENANCE, INSTALLATION AND REPAIR SERVICES,HVAC Systems Maintenance and Repair, Power Plant"
],
"longdesc": "HEATING, VENTILATION AND AIR-CONDITIONING (HVAC) UPGRADES AT THE EQUIPMENT BUREAU FACILITY LOCATED AT 2701 SOUTH TAYLOR STREET IN ARLINTON, VIRIGINIA. THE PROJECT WILL INCLUDE, BUT NOT BE LIMITED TO UPGRADING AND COMPONENT REPLACEMENT OF THE HVAC SYSTEMS AND RELATED CONTROLS SERVING BOTH THE OFFICE/ADMINISTRATIVE/PARTS STORAGE AREAS AND THE VEHICLE REPAIR BAYS. THE WORK SHALL ALSO INCLUDE REVISIONS TO THE ELECTRICAL DISTRIBUTION SYSTEM SERVING THE HVAC SYSTEM. STRUCTURAL REINFORCING ON THE ROOF IS REQUIRED TO SUPPORT NEW HVAC EQUIPMENT. TWO OF THE VEHICLE REPAIR BAYS SHALL BE MODIFIED TO PROVIDE CAPABILITY TO MAINTAIN CNG-FUELED VEHICLES, WHICH SHALL REQUIRE CONSTRUCTION OF A FIRE-RATED ENCLOSURE. ADDITIONALLY THE WORK SHALL INCLUDE A WELDING EXHAUST SYSTEM AND MONITORING OF BUILDING POWER CONSUMPTION AND GENERATOR OPERATION THROUGH THE BUILDING AUTOMATED SYSTEM (BAS).",
"_version_": 1747861007821176800,
"amenddate": "2014-02-18T00:00:00Z",
"buyername": "Angela Gaskins",
"closedate": "2014-02-20T14:30:00Z",
"doccddesc": "Invitation for Bids (IFB)",
"docdeptcd": "S000",
"shortdesc": "HVAC UPGRADES AT THE EQUIPMENT BUREAU FACILITY",
"agencyname": "Other eVA Localities",
"externalid": "638-14",
"internalid": "92807",
"commlinedesc": [
"[]"
],
"lastupdatedate": "2018-10-13T03:05:37Z",
"categoryshortdesc": "Construction",
"openresponsesdate": "2014-02-20T14:30:00Z"
}