Request for Information - Pilot Plant Treatment Equipment

cityoftampa / Water

Description

This is a Request for Information for the City of Tampa's Water Department. The City of Tampa Water Department is requesting planning-level information pertaining to water treatment pilot plant equipment availability, feature options, cost, and delivery times. Pilot plant equipment may have the following characteristics: Approximate 50 gpm capacity Provide skids for the following unit operations separately: Raw water screening (surface water source) Coagulation (conventional & enhanced), flocculation, and sedimentation to include polymer addition functionality Coagulation (conventional & enhanced), flocculation, and ballasted sedimentation to include polymer addition functionality Suspended ion exchange inclusive of a regeneration system Ozonation Alkalinity / pH / stability adjustment to include options for using lime, caustic, and carbon dioxide Corrosion control chemical addition Filtration to accommodate modular media depth, mixed bed, air scour, and automated backwash Sodium hypochlorite and ammonia solution injection with contact chamber A variety of membrane-based treatment options Surge tank, flow meter, flow control, and pump for the purpose of adjusting hydraulic grade line between skids Cart-mounted composite sample collection rig to include a 5-gallon carboy (or similar to collect composite samples) and adjustable flow rate peristaltic pump / tubing. Disinfectant residual decay testing loops (pumps / surge tank for recirculating water through Owner provided distribution piping) Corrosion / stability testing loops for a variety of relevant metals & alloys (iron, copper, lead, etc.) Water conservation demonstration (visually demonstrate the effect of installing water conserving toilets/faucets/heads compared to conventional fixtures). Equipment should be constructed of materials that will not corrode, be BPA free, PFAS/PFOS/PFOA free, NSF compliant, etc. Hand, off, and auto control—hand control should be via panel mounted electro-mechanical devices and auto control should consist of providing a terminal junction box for terminating I/O field wiring on one side and providing terminals for connection to a process instrumentation and control system on the other side (input/output rack(s), programmable logic controllers, operator interface terminals, and SCADA system(s) to be provided by others) Instrumentation appropriate for each unit operation that aligns with water utility sector best practices. Products shall be consistent with Attachment A. Attachment A consists of Chapters 5, 6, 8, and 9 from Basis of Design Summary, I&C dated November 2023. Powered by 480 VAC or lower Bench scale coagulation, flocculation, and settling jar testing setup Bench scale ionic exchange column testing setup Bench testing equipment to measure mass, free and combined chlorine, dissolved ozone, pH, color, turbidity, particle size distributions, slurry density, etc. Bench testing equipment to measure moisture content in solids (oven, filtering ability, balances, etc.) Bench testing equipment to perform sieve analysis on filter and ion exchange media Furnishings for a small laboratory and sample preparation area Chemical storage, pumping, and dosing for sulfuric acid, ferric sulfate, polymer solutions, chloramination (sodium hypo solution + ammonia), lime, caustic, ozone with hydrogen peroxide quenching, carbon dioxide, orthophosphate, fluoride Responses should include manufacturer cut sheets, shop drawings, itemized budget-level cost estimates (US Dollars, inclusive of design, fabrication, shipping, unloading, initial setup & startup services), sales contact information, and customer references (with customer contact information) for the above equipment. Responses may include additional information the responder deems relevant and helpful.

Details

Posted
Mar 24, 2025
Response deadline
Jun 2, 2025, 6:00 PM UTC
Status
closed
Buyer
cityoftampa
Department
Water
Jurisdiction
cityoftampa
Reference #
25-P-00169
Summary
<p>This is a Request for Information for the City of Tampa's Water Department.</p><p style="margin: 0in 0in 8pt; line-height: 107%; font-size: 11pt;">The City of Tampa Water Department is requesting p
Is Paused
false
Template Title
Solicitation (Attach a Document)
Copy Count
0
Government Organization City
Tampa
Government Organization Name
City of Tampa
Government Organization State
FL
Government Organization Website
https://www.tampa.gov/
Government Organization Zip Code
33610
Government Organization Address1
2555 E Hanna Ave
Government Organization Timezone
America/New_York
Government Organization Country Code
US
Government Organization Phone Country
1
Close Out Reason
Request for Information
Closed Substatus
other

Contact

(813)274-8351
Finding similar opportunities…

This listing is a summary from cityoftampa's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.

Raw record
{
  "id": 154738,
  "_slug": "cityoftampa",
  "title": "Request for Information - Pilot Plant Treatment Equipment",
  "status": "closed",
  "summary": "<p>This is a Request for Information for the City of Tampa's Water Department.</p><p style=\"margin: 0in 0in 8pt; line-height: 107%; font-size: 11pt;\">The City of Tampa Water Department is requesting planning-level information pertaining to water treatment pilot plant equipment availability, feature options, cost, and delivery times.&nbsp; Pilot plant equipment may have the following characteristics:&nbsp;</p><ul style=\"margin-bottom: 0in; margin-top: 0px;\"><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Approximate 50 gpm capacity</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Provide skids for the following unit operations separately:&nbsp;<ul style=\"list-style-type: circle; margin-bottom: 0in; margin-top: 0px;\"><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Raw water screening (surface water source)</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Coagulation (conventional &amp; enhanced), flocculation, and sedimentation to include polymer addition functionality</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Coagulation (conventional &amp; enhanced), flocculation, and <u>ballasted</u> sedimentation to include polymer addition functionality</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Suspended ion exchange inclusive of a regeneration system</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Ozonation</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Alkalinity / pH / stability adjustment to include options for using lime, caustic, and carbon dioxide</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Corrosion control chemical addition</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Filtration to accommodate modular media depth, mixed bed, air scour, and automated backwash</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Sodium hypochlorite and ammonia solution injection with contact chamber</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">A variety of membrane-based treatment options</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Surge tank, flow meter, flow control, and pump for the purpose of adjusting hydraulic grade line between skids</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Cart-mounted composite sample collection rig to include a 5-gallon carboy (or similar to collect composite samples) and adjustable flow rate peristaltic pump / tubing.&nbsp;</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Disinfectant residual decay testing loops (pumps / surge tank for recirculating water through Owner provided distribution piping)</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Corrosion / stability testing loops for a variety of relevant metals &amp; alloys (iron, copper, lead, etc.)&nbsp;</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Water conservation demonstration (visually demonstrate the effect of installing water conserving toilets/faucets/heads compared to conventional fixtures).&nbsp;</li></ul></li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Equipment should be constructed of materials that will not corrode, be BPA free, PFAS/PFOS/PFOA free, NSF compliant, etc.&nbsp;&nbsp;</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Hand, off, and auto control&mdash;hand control should be via panel mounted electro-mechanical devices and auto control should consist of providing a terminal junction box for terminating I/O field wiring on one side and providing terminals for connection to a process instrumentation and control system on the other side (input/output rack(s), programmable logic controllers, operator interface terminals, and SCADA system(s) to be provided by others)</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Instrumentation appropriate for each unit operation that aligns with water utility sector best practices.&nbsp;</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Products shall be consistent with Attachment A.&nbsp; Attachment A consists of Chapters 5, 6, 8, and 9 &nbsp;from &nbsp;Basis of Design Summary, I&amp;C dated November 2023.&nbsp; &nbsp;</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Powered by 480 VAC or lower</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Bench scale coagulation, flocculation, and settling jar testing setup</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Bench scale ionic exchange column testing setup</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Bench testing equipment to measure mass, free and combined chlorine, dissolved ozone, pH, color, turbidity, particle size distributions, slurry density, etc.</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Bench testing equipment to measure moisture content in solids (oven, filtering ability, balances, etc.)</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Bench testing equipment to perform sieve analysis on filter and ion exchange media</li><li style=\"margin: 0in 0in 0in 0px; line-height: 107%; font-size: 11pt;\">Furnishings for a small laboratory and sample preparation area</li><li style=\"margin: 0in 0in 8pt 0px; line-height: 107%; font-size: 11pt;\">Chemical storage, pumping, and dosing for sulfuric acid, ferric sulfate, polymer solutions, chloramination (sodium hypo solution + ammonia), lime, caustic, ozone with hydrogen peroxide quenching, carbon dioxide, orthophosphate, fluoride</li></ul><p style=\"margin: 0in 0in 8pt; line-height: 107%; font-size: 11pt;\">Responses should include manufacturer cut sheets, shop drawings, itemized budget-level cost estimates (US Dollars, inclusive of design, fabrication, shipping, unloading, initial setup &amp; startup services), sales contact information, and customer references (with customer contact information) for the above equipment.&nbsp; Responses may include additional information the responder deems relevant and helpful.&nbsp;</p>",
  "isPaused": false,
  "template": {
    "title": "Solicitation (Attach a Document)"
  },
  "addendums": [],
  "copyCount": 0,
  "isPrivate": false,
  "comingSoon": false,
  "created_at": "2025-03-14T20:14:11.492Z",
  "department": {
    "id": 7729,
    "name": "Water"
  },
  "government": {
    "code": "cityoftampa",
    "organization": {
      "city": "Tampa",
      "logo": "https://assets.procurement.opengov.com/logo-uploads/d7f77997-5fe0-463f-be05-88a6c8444efb_data.png",
      "name": "City of Tampa",
      "phone": "(813)274-8351",
      "state": "FL",
      "website": "https://www.tampa.gov/",
      "zipCode": "33610",
      "address1": "2555 E Hanna Ave",
      "address2": null,
      "phoneExt": null,
      "timezone": "America/New_York",
      "countryCode": "US",
      "phoneCountry": "1"
    }
  },
  "financialId": "25-P-00169",
  "closeOutReason": "Request for Information",
  "closedSubstatus": "other",
  "proposalDeadline": "2025-06-02T18:00:00.000Z",
  "releaseProjectDate": "2025-03-24T20:14:46.476Z"
}