GovBidAlerts
← My Opportunities
closed🌐 cpschoolsBid 41-2324

Chiller Replacement Project - Western Branch High School

cpschools / School Plants

Description

The work primarily consists of, but is not limited to, the following: 1. Replacing the existing water-cooled centrifugal chiller with air cooled chiller. Chiller to be sized to accommodate existing connected chilled water load. The new air-cooled chiller will be pre-purchased by Chesapeake Public Schools. 2. Demolition of the existing cooling tower and concrete support pad / piers. 3. Removal of existing chilled water pumps. Installation of new vertical in-line chilled water pumps. 4. Demolition of existing condenser water pumps and condenser water piping within the mechanical room. 5. Demolition of the existing chilled water piping to a point of the flanged connection downstream of the air separator. Provide new air separator and other piping specialties. 6. New chilled water piping above grade in the existing mechanical room. 7. Locate the new chiller in the current location of the cooling tower. 8. Provide interior coating for existing underground condenser water piping to allow its use for chilled water supply / return water piping below grade between chiller and mechanical room. 9. Provide elevated 12” thick slab for chiller support. 10. Minimum 6’ high chain link fence. 11. Provide fill to elevate chiller support slab. 12. Cut and patch existing asphalt between chiller and mechanical room. 13. Provide controls for new chiller. Replace existing 3-way control valves on AHUs to 2-way valves. Reconfigure control system for 2-way, modulating operation. Provide new coil connection components, including automatic balance valves. 14. Demolition of electrical feeders to existing chiller. New electrical connection to air cooled chillers. Feeders to be trenched below grade.

Details

Posted
Apr 9, 2024
Response deadline
Apr 26, 2024, 7:00 PM UTC
Status
closed
Buyer
cpschools
Department
School Plants
Jurisdiction
cpschools
Reference #
Bid 41-2324
Summary
<p>The work primarily consists of, but is not limited to, the following:</p><p>1.&nbsp;&nbsp; Replacing the existing water-cooled centrifugal chiller with air cooled chiller. Chiller to be sized to ac
Is Paused
false
Template Title
IFB Construction (Attach a Document)
Copy Count
1
Government Organization City
Chesapeake
Government Organization Name
Chesapeake Public Schools
Government Organization State
VA
Government Organization Website
https://www.cpschools.com/page/purchasing
Government Organization Zip Code
23322
Government Organization Address1
304 Cedar Road
Government Organization Timezone
America/New_York
Government Organization Country Code
US
Closed Substatus
awarded

Contact

(757)547-0265
Finding similar opportunities…

This listing is a summary from cpschools's open procurement data. We ingest every field the feed publishes; the full solicitation documents are on the source portal.

Raw record
{
  "id": 89223,
  "_slug": "cpschools",
  "title": "Chiller Replacement Project - Western Branch High School",
  "status": "closed",
  "summary": "<p>The work primarily consists of, but is not limited to, the following:</p><p>1.&nbsp;&nbsp; Replacing the existing water-cooled centrifugal chiller with air cooled chiller. Chiller to be sized to accommodate existing connected chilled water load. The new air-cooled chiller will be pre-purchased by Chesapeake Public Schools.</p><p>2.&nbsp;&nbsp; Demolition of the existing cooling tower and concrete support pad / piers.</p><p>3.&nbsp;&nbsp; Removal of existing chilled water pumps. Installation of new vertical in-line chilled water pumps.</p><p>4.&nbsp;&nbsp; Demolition of existing condenser water pumps and condenser water piping within the mechanical room.</p><p>5.&nbsp;&nbsp; Demolition of the existing chilled water piping to a point of the flanged connection downstream of the air separator. Provide new air separator and other piping specialties.</p><p>6.&nbsp;&nbsp; New chilled water piping above grade in the existing mechanical room.</p><p>7.&nbsp;&nbsp; Locate the new chiller in the current location of the cooling tower.</p><p>8.&nbsp;&nbsp; Provide interior coating for existing underground condenser water piping to allow its use for chilled water supply / return water piping below grade between chiller and mechanical room.</p><p>9.&nbsp;&nbsp; Provide elevated 12&rdquo; thick slab for chiller support.</p><p>10.&nbsp; Minimum 6&rsquo; high chain link fence.</p><p>11.&nbsp; Provide fill to elevate chiller support slab.</p><p>12.&nbsp; Cut and patch existing asphalt between chiller and mechanical room.</p><p>13.&nbsp; Provide controls for new chiller. Replace existing 3-way control valves on AHUs to 2-way valves. Reconfigure control system for 2-way, modulating operation. Provide new coil connection components, including automatic balance valves.</p><p>14.&nbsp; Demolition of electrical feeders to existing chiller. New electrical connection to air cooled chillers. Feeders to be trenched below grade.</p>",
  "isPaused": false,
  "template": {
    "title": "IFB Construction (Attach a Document)"
  },
  "addendums": [
    {
      "id": 36465
    },
    {
      "id": 36309
    }
  ],
  "copyCount": 1,
  "isPrivate": false,
  "comingSoon": false,
  "created_at": "2024-04-05T18:30:16.240Z",
  "department": {
    "id": 6198,
    "name": "School Plants"
  },
  "government": {
    "code": "cpschools",
    "organization": {
      "city": "Chesapeake",
      "logo": "https://assets.procurement.opengov.com/logo-uploads/2d91917a-c4f7-4cdf-bc0c-adf9406f31e2_Chesapeake_Public_Schools_logo.png",
      "name": "Chesapeake Public Schools",
      "phone": "(757)547-0265",
      "state": "VA",
      "website": "https://www.cpschools.com/page/purchasing",
      "zipCode": "23322",
      "address1": "304 Cedar Road",
      "address2": null,
      "phoneExt": null,
      "timezone": "America/New_York",
      "countryCode": "US",
      "phoneCountry": "1"
    }
  },
  "financialId": "Bid 41-2324",
  "closeOutReason": null,
  "closedSubstatus": "awarded",
  "proposalDeadline": "2024-04-26T19:00:00.000Z",
  "releaseProjectDate": "2024-04-09T18:31:54.887Z"
}